4.2.7. Wiring

C1
Power filter
LINE
Figure 4.22: Power filter
C2
Fix cables using cable ties
Keep covering it with a cap
1) Connect LAN cable for MONI-CON and SPU
MONI-CON LAN connector
SPU LAN connector
2) Wire the power filter
Warning:
Electric Shock Hazard
Unplug the power of the WR110-JCU before
servicing.
(1) Fix / Connect AC power cable (3pin)
(2) Confirm wiring on the circuit diagram of power
filter label before connecting.
(3) Connect the LINE side to match the line color
of LOAD side.
<Wire color>
Type
P/L
Line
N
Neutral
White
E
Ground
Green
LOAD
3) Insert the cable into the protecting tube.
Protecting Tube 1:
- C1: AC Power cable (3cores)
- C2: LAN cable x2
Protecting Tube 2:
Cover using cap
(*1) Attach cables tightly using cable ties
while leaving extra cable length for
strain relief at all connections.
32
JIS
Black
DO NOT forget to
cover it