20. Service Data

Service data provided are based on the air conditioner running under rated frequency during forced cooling / forced
heating mode.

20.1 Cool Mode Outdoor Air Temperature Characteristic

Condition
- Indoor room temperature: 27°C DryBulb/19°C Wet Bulb
- Unit setting: Standard piping length, forced cooling at 16°C, Hi fan
- Compressor frequency: Rated for cooling operation
- Piping length: 5m
- Voltage: 230/240V
20.1.1
CS-RZ25TKR CU-RZ25TKR
21.000
20.000
19.000
18.000
17.000
16.000
15.000
14.000
16
18
20
22
4.000
3.500
3.000
2.500
2.000
1.500
16
18
20
22
1.300
1.200
1.100
1.000
0.900
0.800
16
18
20
22
24
26
28
30
32
34
36
Outdoor Air Temperature (°C)
24
26
28
30
32
34
36
Outdoor Air Temperature (°C)
24
26
28
30
32
34
36
Outdoor Air Temperature (°C)
230
240
38
40
42
44
46
38
40
42
44
46
189.000
174.000
160.000
145.000
131.000
116.000
38
40
42
44
46
162
Indoor Discharge
Outdoor
Air Temperature
Temperature (°C)
(°C)
16
15.51
25
15.04
35
16.41
46
20.07
Current (A)
Outdoor
Temperature (°C)
230V
16
2.07
25
2.53
35
3.20
46
3.94
Gas Side Piping
Outdoor
Pressure
Temperature (°C)
(MPa)
16
0.812
25
0.949
35
1.094
46
1.270
240V
1.97
2.43
3.10
3.84
(Psi)
118.000
138.000
159.000
184.000