Certification
6.2 EMC and Environmental Type Tests
Damped Os-
cillatory Mag-
netic Field
Environmental Type Tests
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60068-21-1
IEC 60068-21-2
Military Standard Tests
38
Description
Dielectric
Signal Ports
Strength
DC Power Ports
AC Power Ports
Enclosure Ports
Test
Cold Temperature
Humidity (Damp Heat, Cyclic)
Test
MIL-STD-901D
Shock (Hard-Mounted)
MIL-STD-167-1
MIL-STD-461E
Electromagnetic Interference
MIL-STD-1399
MIL-STD-810F
Low Pressure Altitude Storage,
Low Pressure Altitude Opera-
tional, High Temperature Stor-
age, High Temperature Opera-
tional, Low Temperature Stor-
age, Low Temperature Oper-
ational, Temperature Shock
Storage, Humidity, Accelera-
tion, Salt Fog and Vibration
MIL-STD-1275B
Description
Dry Heat
Vibration
Shock
Description
Vibration
Magnetic Field – DC
Magnetic Exposure
Power Quality
Test Levels
2 kV
2 kV
2 kV
100 A/m
Test Levels
Test Ad
-40 °C (-40 °F), 16 Hours
Test Bd
85 °C (185 °F), 16 Hours
Test Db
95% (Non-Condensing),
55 °C (131 °F), 6 Cycles
2g @ 10-150 Hz
30 g @ 11 ms
Test Levels
Grade A, Equipment Class
I, Shock Type A Equipment
Type I (4-33 Hz)
CE101, CE102, CS101, CS114, CS115,
CS116, RE101, RE102, RS101, RS103
Section 070, Part 1
Method 500 Series Procedures
Per Standard
Installation Manual, 01/2020, C79000-G8976-1342-06