Check Weighing; Set The Under And Over Limit Weights - Detecto PS-11 Owner's Manual

Digital portion scale with check weighing mode
Hide thumbs Also See for PS-11:
Table of Contents

Advertisement

The PS-11 allows you to set up the target accept settings for check weighing. The keyboard is
used to enter in your Over and Under check weight limits.

Set the Under and Over Limit Weights

1. Press the ON/OFF key to the turn scale on.
2. The scale will display
Weighing Mode.
3. Press and hold the MODE key until the scale beeps twice
to enter the Check Weighing Mode.
4. With the scale in Check Weighing Mode, the first digit on
the display will be flashing.
5. Press the TARE key to change the value of this digit
from 0 to 9.
6. Press the UNIT key to switch to the next digit, and then press the TARE key to change the
value of this digit from 0 to 9.
7. Repeat step 3 until the desired Under Limit weight has been entered.
8. Once the desired Under Limit weight has been entered, press the MODE/OK key to save it
and advance to Over Limit weight setting.
9. After pressing the MODE/OK key to save the Under Limit
setting, the scale will beep twice, the backlight will turn on
(RED), and the first digit on the display will be flashing.
10. Press the TARE key to change the value of this digit
from 0 to 9.
11. Press the UNIT key to switch to the next digit, and then press the TARE key to change the
value of this digit from 0 to 9.
12. Repeat step 3 until the desired Over Limit weight has been entered.
13. Once the desired Over Limit weight has been entered, press the MODE/OK key to save it.
14. The scale will beep twice, and is now ready for Check Weighing operation.
NOTE: In Check Weighing Mode, the UNIT key function is disabled. Note that the TARE key is
enabled to tare the container weight (ex: a pan or a plate) or zero the display.
To exit the Check Weighing Mode and return to the Normal Weighing Mode, press the MODE key.
The scale will beep once, and the Under annunciator triangle will turn off.
6

CHECK WEIGHING

88888
then change to the Normal
8528-M310-O1 Rev C  PS-11

Advertisement

Table of Contents
loading