General Information; Gas Hook-Up Instructions - Napoleon BILEX730 User Manual

Table of Contents

Advertisement

General Information

This gas grill is certified for outdoor use and should be installed to conform to local codes. Check gas type
and specifications located on the rating plate located on the back panel of the grill.
Universal Liquefied Petroleum Gas Cylinder Specifications
WARNING!
If these instructions are not followed exactly, a fire causing death or serious injury may
occur.
If the gas grill is being supplied with Universal Liquefied Petroleum Gas from a portable cylinder, a
regulator specified by the manufacturer must be used. Cart models have been designed for use for use
with an approved 9 kg size Universal Liquefied Petroleum Gas cylinder (not supplied). The Universal
Liquefied Petroleum Gas cylinder must be equipped with a POL tank valve connection. A dented or rusty
cylinder may be hazardous and should be checked by your Universal Liquefied Petroleum Gas supplier.
Never use a cylinder with a damaged valve. The cylinder supply system must be arranged for vapor
withdrawal and the cylinder shall include a dust cap to protect the cylinder valve. The cylinder shall
incorporate a listed OPD (overfill protection device). Do not store a spare Universal Liquefied Petroleum
Gas cylinder under or near this appliance. Never fill the cylinder beyond 80 percent full.

Gas Hook-Up Instructions

WARNING!
This grill is designed for non-combustible enclosures only, and must be installed and
serviced by a qualified installer to local codes.
WARNING!
Cabinet frame, cabinet, and counter top must be made from non-combustible material.
WARNING!
The pressure supplied to the grill must conform to what is listed on the rating plate of
the grill (2.75 kPA for Universal Liquefied Petroleum Gas, 1.00 kPA WC for Natural Gas). If the supply
pressure is greater, a regulator must be installed.
BUILT IN UNIvERSAL LIqUEFIED PETROLEUM GAS HOOK-UP: The piping up to the gas grill is the
responsibility of the installer and piping should be located as shown in the built-in instructions. A flexible
metal connector is included to simplify the installation of the unit. Connect this flexible metal connector
to the flare fitting on the end of the manifold. Connect the other end of the connector to the gas piping.
Ensure that the connector does not pass through a wall, floor, ceiling or partition, and is protected from
damage. The installation must be performed by a licensed gas fitter in accordance with AS5601 / AG601,
and all connections must be leak tested before operating the grill.
Do not use a hose to connect the unit except to connect the cylinder regulator to the piping system. It
must be connected with rigid pipe, copper tube or an approved flexible metal connector which complies
with with AS5601 / AG601. The gas supply pipe must be sufficiently sized to supply the kPA specified on
the rating plate, based on the length of the piping run. If installing a side burner, a separate line must be
branched off to the side burner unit and enter the side burner opening at the specified location. If the
enclosure is to house a ULPG cylinder, the tank portion of the enclosure must be ventilated according
to local codes, and must not have communication with the cavity used to enclose the gas grill. A ULPG
cylinder cannot be stored below the gas grill.
5
www.napoleongrills.com

Advertisement

Table of Contents
loading