Ac Power Draw And Thermal Dissipation - Crown CTs 1200 Operation Manual

Cts series 2-channel models multi-channel models
Hide thumbs Also See for CTs 1200:
Table of Contents

Advertisement

CTs Power Amplifi ers

8 AC Power Draw and Thermal Dissipation

AC Power Draw and Thermal Dissipation:
Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Measurements made with 120VAC mains. Line current figures for 230VAC units derived by multiplying 120VAC figures by 0.5.
Data based on all channels driven.
At Idle
1/8th Power Pink Noise
Typical of program material
just at clip.
1/3rd Power Pink Noise
Typical of program material
with severe clipping.
Operation Manual
Rated
Line Current
Load
Power
8 Ohms/Ch.
300x2
16 Ohms Bridge
600
4 Ohms/Ch.
300x2
8 Ohms Bridge
600
2 Ohms/Ch.
150x2
4 Ohms Bridge
300
70V/Ch.
300x2
140/200V Bridge 600
8 Ohms/Ch.
300x2
16 Ohms Bridge
600
4 Ohms/Ch.
300x2
8 Ohms Bridge
600
2 Ohms/Ch.
150x2
4 Ohms Bridge
300
70V/Ch.
300x2
140/200V Bridge 600
CTs 600
Line Current
120VAC
230VAC
watts in
60
5.8
2.9
461
7.4
3.7
631
7.0
3.5
583
4.2
2.1
336
8.6
4.3
716
11.3
5.6
968
10.8
5.4
964
6.5
3.3
527
Watts
Thermal Dissipation
watts out
dissapated
Btu/hr
0
60
205
78
383
1307
78
554
1890
38
545
1859
75
261
892
200
516
1760
204
764
2608
102
862
2942
207
320
1091
kcal/hr
52
330
477
469
225
444
657
742
275