Description
The TPMC-L-IMC interface module is included with
the TPMC-15-CH-L, TPMC-15-QM-L,
TPMC-17-CH-L, and TPMC-17-QM-L touchpanels.
The TPMC-L-IMC is used to deliver power from a
power supply to a remotely located wall mount
touchpanel. The TPMC-L-IMC converts the cable
(used by the touchpanel's included power supply) to
two wires (see chart in following column), which
allows a wall mount touchpanel to be installed up to
60 feet from its power supply. The wire runs are
terminated on the rear of the TPMC-15/17 wall
mount touchpanel where they are converted to the
cable-type required by the touchpanel. An LED
indicates when power is supplied to the
TPMC-L-IMC. The TPMC-L-IMC has a mounting
flange to secure the unit to a mounting surface or
the rear of a rack as shown in the following diagram.
The TPMC-L-IMC should be installed near the power
supply.
Physical Views of the TPMC-L-IMC
3.43 in
2.53 in
(8.70 cm)
(6.42 cm)
1.05 in
(2.67 cm)
Installation:
CAUTION: Ensure that the power is disconnected
during installation.
CAUTION: Only the included Crestron power
supply should be used.
Crestron Electronics, Inc.
15 Volvo Drive
Rockleigh, NJ 07647
Tel: 888.CRESTRON
Fax: 201.767.7576
Interface Module: TPMC-L-IMC
2.14 in
(5.42 cm)
1.97 in
(5.00 cm)
2.23 in
(5.66 cm)
1. As shown in the following diagram, connect the
power wires from the TPMC-L-IMC to the rear of
the touchpanel using the supplied connectors.
Crestron recommends using two 60 foot runs (or
less) of 14-gauge stranded wire between the
touchpanel and the TPMC-L-IMC.
Hardware Hookup
PWR PORT ON BOTTOM OF
PWR IN:
FROM EXTERNAL
POWER SUPPLY
Alternatively, a single wire can be run over a
shorter distance. Smaller gauge wires can be
used for shorter runs as well. Refer to the
following table for wiring alternatives.
Recommended Wire Lengths
(Between TPMC-L-IMC and Touchpanel)
WIRE
SINGLE WIRE
GAUGE
(FEET)
14 AWG
30
2
(2.5 mm
)
16 AWG
20
2
(1.5 mm
)
NOTE: If running a single wire, either PWR
OUT connector can be used. Observe polarity
when terminating wire (+ to + and – to –).
2. Connect the power cable from the external
power supply to the PWR IN port of the
TPMC-L-IMC. The PWR LED will illuminate.
Specifications subject to change without notice.
CABLE CONNECTED TO
TOUCHPANEL
TO TOUCHPANEL:
(60 ft MAX @ 14 GAUGE x2)
OBSERVE POLARITY
(+ to + and – to –)
DOUBLE WIRE
(FEET)
60
40
Data Sheet – DOC. 6385
(2013189)
www.crestron.com
07.05

Advertisement

loading

Summary of Contents for Crestron TPMC-L-IMC

  • Page 1 The TPMC-L-IMC interface module is included with the TPMC-15-CH-L, TPMC-15-QM-L, TPMC-17-CH-L, and TPMC-17-QM-L touchpanels. The TPMC-L-IMC is used to deliver power from a power supply to a remotely located wall mount touchpanel. The TPMC-L-IMC converts the cable (used by the touchpanel’s included power supply) to...
  • Page 2: Return And Warranty Policies

    CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for...