Chapter 4

Far End Looped Back Test

Network Interface Test

61200060L1-1
Testing Example
Prior to actually using the TSU to pass data, it is
recommended to run tests on the circuit.
The testing consists of sending a test pattern from end to end
and checking for errors in the pattern. There are two types of
tests used to accomplish this.
Send the pattern from one end and loopback the far end.
Send the pattern from both ends and check at both ends.
Two types of tests can be executed with the far end looped.
The first is a check of the network and the network interfaces
at both ends (511). The second is a check of the DTE port.
The Network Interface Test can be run with any channel
setup because the 511 pattern is always sent in the occupied
channels.
1.
At the main menu, use the scroll keys to place the cursor
on
.
4)TEST
2.
Press
ENTER
The first two test submenu items display.
1 ) M O N I T O R
2 ) C O N F I G
to select.
TSU User Manual
3 ) U T I L
4 ) T E S T
4-1