Lennox SL280UHNV Series Unit Information page 20

Communicating-enabled units
Hide thumbs Also See for SL280UHNV Series:
Table of Contents

Advertisement

BLOWER DATA
SL280UH100NV60C BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR, RETURN AIR FROM BOTH SIDES OR RETURN AIR FROM BOTTOM AND ONE SIDE
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
Heating Speed
1
DIP Switch
Settings
+24%
+18%
+12%
+6%
Factory Default
–6%
–12%
–18%
Cooling Speed
1
DIP Switch
Low
Settings
+
1200
Factory Default
1075
1010
SL280UH100NV60C BLOWER PERFORMANCE (less filter)
Single Side Return Air - Air volumes in bold require Optional Return Air base and field fabricated transition to accommodate 20 x
25 x 1 in. air filter in order to maintain proper air velocity.
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
Heating Speed
1
DIP Switch
Settings
+24%
+18%
+12%
+6%
Factory Default
–6%
–12%
–18%
Cooling Speed
1
DIP Switch
Low
Settings
+
1140
Factory Default
1040
930
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings.
1
Factory default setting.
2
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28%, 38%, 70% and 100% of the selected second stage cooling speed - minimum 450 cfm.
Lennox iHarmony
Zoning System Applications - Minimum blower speed is 450 cfm.
®
First Stage Heating Speed - cfm
1745
1670
1580
1500
1425
1310
1260
1190
First Stage Cooling Speed - cfm
Medium-Low
Medium-High
1250
1380
1150
1275
1050
1150
First Stage Heating Speed - cfm
1600
1530
1440
1370
1290
1260
1175
1065
First Stage Cooling Speed - cfm
Medium-Low
Medium-High
1180
1300
1060
1190
970
1070
HEATING
Second Stage Heating Speed - cfm
COOLING
Second Stage Cooling Speed - cfm
High
Low
2
1585
1710
1460
1570
1320
1410
HEATING
Second Stage Heating Speed - cfm
COOLING
Second Stage Cooling Speed - cfm
High
Low
2
1480
1615
1365
1460
1240
1325
Page 20
1930
1825
1740
1655
1565
1470
1390
1300
Medium-Low
Medium-High
1790
1950
1610
1785
1480
1625
1785
1685
1600
1515
1415
1390
1290
1190
Medium-Low
Medium-High
1695
1865
1530
1690
1380
1520
High
2
2270
2065
1880
High
2
2160
1960
1760