Honeywell NOTIFIER AM-8000 Programming Manual page 6

Intelligent addressable fire detection
Hide thumbs Also See for NOTIFIER AM-8000:
Table of Contents

Advertisement

F
R
O
F
R
O
EVACUATION:
You must know the level 2 password to perform this operation..
Control for the activation of the Siren output and of all output modules programmed with SW-TYPE ID = HORN in absence
of Alarms and Faults. If you press this button once more all the previously activated outputs will be deactivated.
END DELAY:
This button is active only in case of alarm if the immediate activation of the siren outputs in the exclusions menu has been
excluded. The control unit delays the activation of the above-mentioned outputs for the programmed times in the
programmed menu. ( Prog\ Sist\Al. Output Timing ). During the delay time the Active Delay led flashes and it is possible to
re-set the current delay through the Delay Re-set key.
SILENCE ALARM / FAULT:
by pressing this key, the operator can silence the Panel buzzer and is enabled to perform a RESET.
SILENCE / RESOUND SIREN:
You must know the level 2 password to perform this operation..
In case of alarm the following devices are activated: Siren Output, Output modules programmed with SW-Type-ID=HORN ,
the output modules activated for CBE associations
By pressing this key, you can de-activate the following devices:
Siren Output
Output modules programmed through Type-ID HORN enabled for silencing
All output modules activated through CBE associations and enabled for silencing
A subsequent pressure of this key will re-activate :
Siren Output
Output modules programmed through Type-ID HORN
All the output modules de-activated from the previous Silencing
RESET:
the pressure of this key deletes the alarm or fault memory of the current points.
It de-activates the siren and turns off all light signalling of sensors in alarm.
To perform this operation you must know the level 2 password..
Keys to be used: DURING THE PROGRAMMING or TO ENTER THE PASSWORDS
ARROWS: they are used to perform some selections.
NOTE: pressing and holding one of these keys for more than 1 second, you obtain the key automatic
repetition
ENTER: after performing a selection, it confirms the entered datum.
ESCAPE: "Back", it has the menu exit function
Pag. 2
NOTIFIER ITALIA
N
T
P
A
N
E
L
C
O
N
T
P
A
N
E
L
C
O
FUNCTION KEYS in LCD TOUCH SCREEN:
These keys are displayed in the bottom of the LCD screen.
Activate the corresponding functions. These functions change according to
the selected menus.
Example: in the system status display, these keys allow the access to the
Programming, Utilities, Exclusion menus or the Test menu.
.
Programming Manual
Doc. M-160.2-AM-8000-ENG Rev A1
N
T
R
O
L
S
A
N
D
N
T
R
O
L
S
A
N
D
K
e
y
s
w
i
t
h
d
e
d
i
c
K
e
y
s
w
i
t
h
d
e
d
i
c
S
I
G
N
A
L
L
I
N
G
S
I
G
N
A
L
L
I
N
G
a
t
e
d
f
u
n
c
t
i
o
n
s
a
t
e
d
f
u
n
c
t
i
o
n
s
AM8000_manu-prog-ENG
S
S
SERIEAM

Advertisement

Table of Contents
loading

Table of Contents