Installation - Crown EL-20 Installation & Operation Manual

Self-generating steam jacketed kettles
Table of Contents

Advertisement

I
NSTALLATION

Installation

U
NPACKING
Immediately after unpacking the steamer, check for possible shipping damage. If the steamer is found to be damaged,
save the packaging material and contact the carrier within 15 days of delivery.
Prior to installation, verify that the type of gas supply (natural or propane) and electrical service agree with the
specifications on the rating plate located on the left side panel as you face the front of the braising pan. If the supply
and equipment requirements do not agree, contact your dealer immediately.
Installation Instructions
1. The kettle must be installed in accordance with:
1. State and/or local codes.
2. In the USA, the National Electrical code, ANSI/NFPA-70 (latest edition). In Canada, the Canadian Electrical
Code, Part 1, CSA Standard C22.1 (latest edition).
2. Set the kettle in the installation location.
3. With the kettle in position, place a carpenter's level on top of the kettle and turn the adjustable feet to level kettle
side-to-side and front to back. On EP models use shims to level kettle.
4. Mark hole locations on floor through anchoring holes provided in flanged adjustable feet, or holes provided on
pedestal base.
5. Remove kettle and drill holes in locations marked on the floor (See Installation Diagram). Insert proper anchoring
devices to accommodate 5/16" size lag bolts (not supplied).
6. Reposition kettle. Re-level kettle by making necessary adjustments on flanged feet or shims.
7. Bolt down kettle and seal with Silastic or other equivalent sealing compound. Sealant must be applied not only to bolt
heads but also around flanges or pedestal base making contact with floor surface to fulfill NSF requirements. Wipe off
excess sealant immediately.
Disconnect the electrical power supply and place a tag at the disconnect switch to indicate you are
working on the circuit. Disconnect the electrical power supply and place a tag at the disconnect
6
PAGE
OF 28
IMMEDIATELY INSPECT FOR SHIPPING DAMAGE
switch to indicate you are working on the circuit.
INSTALLATION & OPERATION MANUAL 10068 REV 0 (05/21)
Self-Generating Steam Jacketed Kettles
WARNING

Advertisement

Table of Contents
loading

Table of Contents