Siemens SITRANS DA400 Operating Instructions Manual page 81

Process monitoring
Table of Contents

Advertisement

PROFIBUS PA
PROFIBUS PA
Power supply
Bus voltage
Current consumption
Bus connection with FISCO supply unit, ia/ib group IIC or IIB with:
Bus connection with linear barrier, ia/ib group IIC with:
Communication
Layer 1+2 according to PROFIBUS PA, transmission technique according to IEC 1158-2
PC configuration software
SITRANS DA400 for material flow monitoring with protection against explosion
Operating Instructions, 09/2007, A5E00841152-01
Maximum supply voltage U
Maximum short circuit current I
Maximum power P
i
Maximum supply voltage U
Maximum short circuit current I
Maximum power P
i
Internal capacity Ci
Internal inductance Li
C2 connections
Device profile
Device address
Clamps 91 and 92
Clamps 93 and 94
Bus-powered
9 ... 24 V
10.5 mA ± 10 %
≤ 17.5 V
i
≤ 380 mA
i
≤ 5.32 W for II B
≤ 2.52 W for II C
≤ 24 V
i
≤ 200 mA
i
≤ 1.2 W
negligible
≤ 0.8 µH
Four connections are supported on master class
2.
PROFIBUS PA profile V3.0 Rev. 1, Class B
1 ... 126; 126 (delivery state)
SIMATIC PDM (not supplied with the device)
Technical data
9.1 Device technical data
81