UNIT SIZE
NOMINAL CAPACITY (tons)
OPERATING WEIGHT (lb)
Unit
Al/Al*
Economizer
Durablade
Parablade
Roof Curb†
COMPRESSOR
Quantity
No. Cylinders (per circuit)
Oil (oz)
REFRIGERANT TYPE
Operating Charge (lb-oz)
Circuit 1
Circuit 2
CONDENSER COIL
Rows...Fins/in.
Total Face Area (sq ft)
CONDENSER FAN
Nominal Cfm
Quantity...Diameter (in.)
Motor Hp...Rpm
Watts Input (Total)
EVAPORATOR COIL
Expansion Device
Rows...Fins/in.
Total Face Area (sq ft)
EVAPORATOR FAN
Quantity...Size (in.)
Type Drive
Nominal Cfm
Motor Hp
Maximum Continuous Bhp
Motor Frame Size
Nominal Rpm High/Low
Fan Rpm Range
Motor Bearing Type
Maximum Allowable Rpm
Motor Pulley Pitch Diameter A/B (in.)
Nominal Motor Shaft Diameter (in.)
Fan Pulley Pitch Diameter (in.)
Belt, Quantity...Type...Length (in.)
Pulley Center Line Distance (in.)
Speed Change per Full Turn of
Movable Pulley Flange (rpm)
Movable Pulley Maximum Full Turns
From Closed Position
Factory Setting
Factory Speed Setting (rpm)
Fan Shaft Diameter at Pulley (in.)
HIGH-PRESSURE SWITCH (psig)**
Standard Compressor Internal Relief
Cutout
Reset (Auto.)
LOW-PRESSURE SWITCH (psig)**
Cutout
Reset (Auto.)
FREEZE PROTECTION THERMOSTAT (F)**
Opens
Closes
OUTDOOR-AIR INLET SCREENS
Quantity...Size (in.)
RETURN-AIR FILTERS
Quantity...Size (in.)
LEGEND
Al
— Aluminum
Bhp
— Brake Horsepower
FIOP — Factory-Installed Option
TXV
— Thermostatic Expansion Valve
*Evaporator coil fins/condenser coil fins.
†Weight of 14-in. roof curb.
**Requires the accessory controls upgrade kit.
SPECIFICATIONS — 558D036-072
036
3
365
34
42
115
1
2
50
3-6
1...17
7.36
4100
1...22.0
1
...1100
4
325
Enhanced Copper Tubes, Aluminum Double-Wavy Fins
2...15
4.17
Std
1...10 x 10
Alt
1...10 x 10
Std
Direct
Alt
Belt
1200
Std
Alt
Std
.34
Alt
1.00
Std
48
Alt
48
Std
860/800
Alt
Std
Alt
760-1000
Ball
2100
Std
Alt
1.9/2.9
Std
1
2
Alt
1
2
Std
Alt
4.5
Std
Alt
1...A...34
Std
Alt
10.0-12.4
Std
Alt
48
Std
Alt
5
Std
Alt
3
Std
Alt
856
1
2
††Circuit 1 consists of lower portion of both the condenser and evaporator coils, and
Circuit 2 consists of the upper portion of both coils.
The 559F300 units require 2-in. industrial-grade filters capable of handling face ve-
locities up to 625 ft/min (such as American Air Filter no. 5700 or equivalent).
NOTE: The 036-150 units have a loss-of-charge/low-pressure switch (accessory or op-
tion) located in the liquid line. The 180-300 units have a low-pressure switch (standard)
located on the suction side.
14
048
4
375
34
42
115
Hermetic
1
2
50
R-22
4-11
Enhanced Copper Tubes, Aluminum Lanced Fins
1...17
1...17
11.39
13.19
Propeller Type
4100
4100
1...22.0
1...22.0
1
...1100
1
...1100
4
4
325
Acutrol™ Feed Device
2...15
3...15
5.5
Centrifugal Type
1...10 x 10
1...11 x 10
1...10 x 10
1...10 x 10
Direct
Direct
Belt
1600
2000
.75
1.00
48
48
1075/970
1075/970
835-1185
900-1300
Ball
2100
2100
1.9/2.9
2.4/3.4
1
2
1
2
4.0
1...A...34
1...A...39
10.0-12.4
14.7-15.5
70
5
3
975
1060
1
2
450 ± 50
428
320
7 ± 3
22 ± 7
30 ± 5
45 ± 5
Cleanable
1...20 x 24 x 1
Throwaway
2...16 x 25 x 2
060
072
5
6
395
470
34
34
42
42
115
115
1
1
2
2
50
54
5-13
7-10
2...17
10.42
4100
1...22.0
1
...1100
4
325
325
4...15
5.5
5.5
1...10 x 10
Belt
Belt
2400
1.20
2.40
1.80
48
56
48
1070-1460
Ball
Ball
2100
2.8/3.8
1
5
2
8
1
2
4.5
4.5
1...A...40
14.7-15.5
80
80
5
5
3
3
1225
1
1
2
2
500 ± 50
428
320