Download Print this page

Maintenance - Lennox 13HPX Series Unit Information

Hide thumbs Also See for 13HPX Series:

Advertisement

Table 23. Normal Operating Pressures − Liquid +10 & Vapor +5 PSIG*
13HPX−018
13HPX−024
Liquid/
5F (5C)**
Vapor
65 (18)
234 / 142
258 / 140
75 (24)
273 / 144
299 / 142
85 (29)
316 / 145
347 / 145
95 (35)
365 / 148
399 / 148
105 (41)
421 / 151
460 / 150
115 (45)
492 / 152
534 / 152
60 (15)
325 / 130
353 / 130
50(10)
309 / 114
330 / 109
40 (4)
293 / 96
307 / 90
30 (−1)
278 / 79
291 / 75
20 (−7)
264 / 65
276 / 59
*These are most−popular−match−up pressures. Indoor match up, indoor air quality, and indoor load cause pressures to vary.
**Temperature of the air entering the outside coil.
Table 24. HFC−410A Temp. (°F) − Pressure (Psig)
°F
Psig
°F
Psig
−40
10.1
21
80.5
−35
13.5
22
82.3
−30
17.2
23
84.1
−25
21.4
24
85.9
−20
25.9
25
87.8
−18
27.8
26
89.7
−16
29.7
27
91.6
−14
31.8
28
93.5
−12
33.9
29
95.5
−10
36.1
30
97.5
−8
38.4
31
99.5
−6
40.7
32
100.8
−4
43.1
33
102.9
−2
45.6
34
105
0
48.2
35
107.1
36
109.2
1
49.5
2
50.9
37
111.4
3
52.2
38
113.6
4
53.6
39
115.8
5
55
40
118
6
56.4
41
120.3
7
57.9
42
122.6
8
59.3
43
125
9
60.8
44
127.3
10
62.3
45
129.7
11
63.9
46
132.2
12
65.4
47
134.6
13
67
48
137.1
14
68.6
49
139.6
15
70.2
50
142.2
16
71.9
51
144.8
17
73.5
52
147.4
18
75.2
53
150.1
19
77
54
152.8
20
78.7
55
155.5
13HPX−XXX−230−01 through 13HPX−XXX−230−03
13HPX−030
13HPX−036
Liquid /
Liquid /
Vapor
Vapor
238 / 137
278 / 138
322 / 140
369 / 143
425 / 144
487 / 147
328 / 127
313 / 110
297 / 93
284 / 77
271 / 62
°F
Psig
°F
Psig
56
158.2
91
278.2
57
161
92
282.3
58
163.9
93
286.5
59
166.7
94
290.8
60
169.6
95
295.1
61
172.6
96
299.4
62
175.4
97
303.8
98
308.2
63
178.5
64
181.6
99
312.7
65
184.3
100
317.2
66
187.7
101
321.8
67
190.9
102
326.4
68
194.1
103
331
69
197.3
104
335.7
70
200.6
105
340.5
71
203.9
106
345.3
72
207.2
107
350.1
73
210.6
108
355
74
214
109
360
75
217.4
110
365
76
220.9
111
370
77
224.4
112
375.1
78
228
113
380.2
79
231.6
114
385.4
80
235.3
115
390.7
81
239
116
396
82
242.7
117
401.3
83
246.5
118
406.7
84
250.3
119
412.2
85
254.1
120
417.7
86
258
121
423.2
87
262
122
428.8
88
266
123
434.5
89
270
124
440.2
90
274.1
125
445.9
13HPX−042
Liquid/
Liquid
Vapor
/ Vapor
Cooling
260 / 136
231 / 135
303 / 140
267 / 138
348 / 143
314 / 140
398 / 145
367 / 143
452 / 148
414 / 146
512 / 151
473 / 148
Heating
350 / 131
360 / 135
331 / 107
340 / 110
314 / 88
324 / 91
290 / 74
307 / 73
283 / 58
298 / 61
E − Oil Charge
See compressor nameplate.
IV − MAINTENANCE
Electric shock hazard. Can cause inju-
ry or death. Before attempting to per-
form any service or maintenance, turn
the electrical power to unit OFF at dis-
connect switch(es). Unit may have
multiple power supplies.
Maintenance and service must be performed by a qualified
installer or service agency. At the beginning of each cooling
season, the system should be checked as follows:
Outdoor Unit
1. Clean and inspect outdoor coil (may be flushed with a
water hose). Ensure power is off before cleaning.
2. Outdoor unit fan motor is pre−lubricated and sealed. No
further lubrication is needed.
3. Visually inspect all connecting lines, joints and coils for
evidence of oil leaks.
4. Check all wiring for loose connections.
5. Check for correct voltage at unit (unit operating).
6. Check amp draw on outdoor fan motor.
Unit nameplate__________Actual__________.
7. Inspect drain holes in coil compartment base and clean
if necessary.
NOTE - If insufficient heating or cooling occurs, the unit
should be gauged and refrigerant charge should be
checked.
Indoor Coil
1. Clean coil if necessary.
2. Check connecting lines, joints and coil for evidence of
oil leaks.
Page 17
13HPX−048
13HPX−060
Liquid /
Liquid /
Vapor
Vapor
246 / 134
256 / 116
286 / 136
298 / 123
330 / 138
345 / 131
379 / 140
395 / 135
432 / 143
450 / 138
492 / 146
512 / 141
361 / 130
370 / 127
334 / 100
350 / 102
302 / 92
331 / 81
300 / 73
309 / 62
286 / 60
300 / 56
WARNING
13HPX−061
Liquid/
Vapor
237 / 135
275 / 137
317 / 139
366 / 141
417 / 144
472 / 147
386 / 122
342 / 81
332 / 76
322 / 73
304 / 59