Specifications; Serial Number And Rating Label Location - Miller Electric COOLMATE 4 Owner's Manual

Hide thumbs Also See for COOLMATE 4:
Table of Contents

Advertisement

3.
Important Information Regarding CE Products (Sold Within The EU)
!
This equipment shall not be used by the general public as the EMF limits for the general public might be exceeded during welding.
This equipment is built in accordance with EN 60974−1 and is intended to be used only in an occupational environment (where the general public
access is prohibited or regulated in such a way as to be similar to occupational use) by an expert or an instructed person.
Wire feeders and ancillary equipment (such as torches, liquid cooling systems and arc striking and stabilizing devices) as part of the welding
circuit may not be a major contributor to the EMF. See the Owner's Manuals for all components of the welding circuit for additional EMF exposure
information.
S
The EMF assessment on this equipment was conducted at 0.5 meter.
S
At a distance of 1 meter the EMF exposure values were less than 20% of the permissible values.
4.

Specifications

Ref. 1228 574-B
5.

Serial Number And Rating Label Location

The serial number and rating information for this product is located on the lower right side. Use rating label to determine input power requirements
and/or rated output. For future reference, write serial number in space provided on cover of this manual.
6.
Warning Label Definitions For CE Products
6
1
Warning! Watch Out! There are
possible hazards as shown by the
symbols.
2
Electric shock from wiring can kill.
3
Disconnect input plug or power before
working on machine.
OM-624 Page 2
Recirculating Coolant System For Water-Cooled GTAW Torches And GMAW Guns
Use With Guns/Torches Rated Up To 600 Amperes
IP Rating: 23 − Not Intended For Use In Heavy Rain, Or Near Splashing Water
4 gal (15 L) Coolant Tank Capacity;
Maximum Cooling Capacity: 5,500 W (18,000 BTU/hr) @ 5.9 qt/min (5.6 L/min)
IEC Cooling Capacity: 1,780 W (6,070 BTU/hr) @ 1.1 qt/min (1 L/min)
IEC Cooling Capacity States That The Water Inlet Temperature Can Not Exceed 40° C Above Ambient
Temperature At A 1L/ Min Flow Rate.
Dimensions: 18-3/4 in. (476 mm) Long, 15-1/4 in. (387 mm) Wide, 16-1/4 in. (413 mm)
Weight: 44 lb (20 kg)
115 Volt, 5.9 Amperes 60 Hertz, 4.7 Amperes 50 Hertz, Single−Phase Input Power
1
2
7
4
Moving parts, such as fans, can cut
fingers and hands and cause injury.
Keep away from moving parts.
5
Wear safety glasses with side shields.
6
Read the Owner's Manual before
working on this machine.
7
Read the labels on the welding power
3
4
8
source, wire feeder, or other major
equipment for welding safety
information.
8
Recycle or dispose of used coolant in
an environmentally safe way.
9
Do not remove or paint over (cover)
the label.
5
S-180 663
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

042288015

Table of Contents