Service and maintenance
8.2 Description of maintenance and repair work
8.2.6.3

Adjusting the air gap

Switch off the power supply to the drive unit
The brake must be in a torque-free condition.
Secure the drive unit to prevent it from being started up unintentionally.
Attach a warning notice to the start switch.
Decrease of braking effect due to contamination
Do not allow oil or grease to come into contact with friction surfaces.
Figure 8-2
Procedure
1. Remove the fan cover.
2. Loosen the fastening screws of the brake.
3. Screw the sleeve screws further into the magnet part using an open-ended spanner.
4. Tighten the fastening screws of the brake.
5. Check the air gap s
6. Rectify the air gap s
7. When combined with manual brake release:
Check the setting dimension "s" and correct "s" if necessary.
8. Mount the fan cover.
You have now set the air gap.
58
WARNING
WARNING
Setting dimension s
, in the vicinity of the screws using a feeler gauge.
if necessary and check it again.
Operating Instructions, 02/2015, 70000004023775
BA 2320

Advertisement

Table of Contents
loading

Table of Contents