Download Print this page

BEA MAGIC SWITCH MS09 Quick Start Manual page 3

Ip65, touchless, activation sensor

Advertisement

3
SETTINGS & ADJUSTMENTS
potentiometer
Potentiometer: Detection Zone*
countclockwise = decrease (4'' minimum)
clockwise = increase (24'' maximum)
TIMED MODE – Recommended for automatic door applications. In Timed Mode, a detection activates the
relay and the relay holds for a predetermined amount of time (0.5 seconds, not adjustable).
TOGGLE MODE – Recommended for switch applications. In Toggle Mode, a detection activates the relay and a
second detection deactivates the relay. The relay will hold indefinitely until a second detection occurs.
For the 900 MHz wireless programming instructions, please reference BEA User's Guide 75.5937 which
comes with the 900 MHz wireless receiver (sold separately).
TROUBLESHOOTING
Sensor does not seem to
detect
Sensor stays in detection
75.5746.05 MS09 20210115
DIP 1
DIP 2
SENSOR FUNCTIONALITY
WIRELESS FUNCTIONALITY
Bad or no power
Detection range too short
Incorrect wiring
Environmental conditions
Incorrect wiring
Wrong output mode
Can't find your answer? Visit www.beainc.com or
scan QR code for Frequently Asked Questions!
4"
MS09
* Detection range is dependent upon
object size, object orientation, object
speed, and environmental conditions.
DIP 1: Timed/Toggle
on (switch up) = toggle mode
off (switch down) = timed mode
0.5 sec only; not adjustable
DIP 2: LED
on (switch up) = LED on when not in detection
off (switch down) = LED on when in detection
Check power supply.
Adjust detection zone potentiometer.
Check wiring.
Remove moving objects from around sensor.
Check wiring (NO and NC).
Switch output mode to TIMED.
Detection
Range*
24"
Page 3 of 4

Advertisement

loading