UNIT SIZE - SERIES
OPERATING WT (Lb)
ELECTRICAL
Unit Volts—Hertz—Phase
Operating Voltage Range*
Compressor— Rated Load Amps
Locked Rotor Amps
Condenser Fan Motor—Full Load Amps
Min Unit Ampacity for Wire Sizing
Min Wire Size (60°C Copper) AWG†
Min Wire Size (75°C Copper) AWG†
Max Wire Length (60°C) (Ft)‡
Max Wire Length (75°C) (Ft)‡
Max Branch Circuit Fuse Size**
COMPRESSOR AND REFRIGERANT
Compressor—Manufacturer & Type
Temperature & Current Protection
Refrigerant—R-22 Amount (Lb)
CONDENSER COIL AND FAN
Coil Face Area (Sq Ft)
Fins per In.—Rows—Circuits
Fan Motor—HP, Type, & RPM
Volts—Hertz—Phase
Condenser Airflow (CFM)
OPTIONAL EQUIPMENT
Support Feet Kit
Coastal Filter
Time-Delay Relay
Cycle Protector
Crankcase Heater
Start Assist—Capacitor/Relay Type
Start Assist—PTC Type
TXV Kit (RPB)
TXV Kits (Hard Shutoff)
Low-Pressure Switch
High-Pressure Switch
Filter Drier
Evaporator Freeze Thermostat††
Liquid-Line Solenoid Valve
Winter Start Control††
Low-Ambient Kit
Low-Ambient Controller
MotorMaster® Control‡‡
Ball Bearing Fan Motor
Thermostat, Auto Changeover,
Non-Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool
Thermostat, Auto Changeover,
7-Day Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool
Builder's Thermostat, Manual
Changeover, Non-Programmable,
°F/°C, 1-Stage Heat, 1-Stage Cool
Thermidistat™ Control—Programmable/
Non-Programmable Thermostat with
Humidity Control
Outdoor Air Temperature Sensor
Backplate for Non-Programmable
Thermostat
Backplate for Builder's Thermostat
Backplate for Programmable Thermostat
Thermostat Conversion Kit (4 to 5 wire)
— 10 Pack
* Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure.
Copper wire must be used from service disconnect to unit.
† If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70).
The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70)
Article 336-26.
‡ Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2 percent.
All motors/compressors contain internal overload protection.
** Time-delay fuse.
†† Use with Low-Ambient Controller.
‡‡ Fan motor with ball bearings required.
SPECIFICATIONS Continued
042-E
213
208/230—60—1
187—253
20.0
104.0
1.1
26.1
10
10
96
91
40
6.68
15.2
25—1—3
1/5 PSC & 825
3000
KSACY0101AAA
KSAHS1501AAA
KAATX0501RPB
KSATX0601HSO
HC38GE231 (RCD)
—5—
048-E/F
247
208/230—60—1
187—253
23.7/21.3
129.0/137.0
1.4
31.0/28.0
8/10
10
71
68
50/40
Copeland Scroll
Internal Line Break
6.34
1/4 PSC & 1100
208/230—60—1
3300
KSASF0101AAA
KAACF0201MED
KAATD0101TDR
Standard
KAACH1201AAA
KAACS0201PTC
KAATX0601RPB
KSATX0701HSO
KAALP0101LPS
KSAHI0101HPS
P502-8163S (RCD)
KAAFT0101AAA
KAALS0101LLS
KAAWS0101AAA
KSALA0201R22
P251-0083 (RCD)
32LT660004 (RCD)
HC40GE232 (RCD)
TSTATBBNAC01-B
TSTATBBPAC01-B
TSTATBBBAC01-B
TSTATBBPRH01-B
TSTATXXSEN01-B
TSTATXXNBP01
TSTATXXBBP01
TSTATXXPBP01
TSTATXXCNV10
060-E
287
208/230—60—1
187—253
28.8
169.0
1.4
37.4
8
8
104
99
60
9.25
18.3
25—1—4
KSAHS1601AAA
KAATX0701RPB