Bryant 597C (60 Hz User Manual

Bryant 597C (60 Hz User Manual

Electric air conditioner

Advertisement

ELECTRIC
AIR CONDITIONER
The Reliant AeroQuiet System (AQS) consists of 3 design fea-
tures to achieve ultra-low sound ratings.
Aerocoustic Design featuring the Aeromax opening and wire
dome top results in quieter and more efficient operation.
Energy-Efficient Fan and Fan Motor provide a slower fan
motor, reducing noise and improving efficiency.
Advanced Sound Hood to muffle noise from operation.
Model 597C Energy-Efficient Air Conditioners incorporate inno-
vative scroll compressor technology to provide quiet, reliable
cooling performance. Built into these units are the features most
desired by homeowners today including SEER ratings up to 14.0
when combined with specific Bryant equipment. All models are
listed with UL, c-UL, ARI, CEC, and CSA-EEV. The 597C meets
the Energy Star
guidelines for energy efficiency.
®
AVAILABLE OPTIONS
DURAGUARD™ COIL PROTECTION —Made of a coated steel
wire grid with vertical 3/8 in. spacing, is designed to help protect
the coil from inclement weather, vandalism, and incidental hits.
It provides protection while not restricting airflow and maintain-
ing ease of coil inspection and cleaning.
ELECTRICAL RANGE —All units are offered in 208/230-v sin-
gle phase only.
WIDE RANGE OF SIZES —Available in 7 nominal sizes from
018 through 060 to meet the needs of residential and light com-
mercial applications.
WEATHER-PROTECTIVE CABINET —Steel is galvanized and
coated with a layer of zinc phosphate. A coat of modified poly-
ester powder is then applied and baked on, providing each unit
with a durable finish that will last for many years.
All screws on cabinet exterior are coated for a long-lasting, rust-
resistant, quality appearance.
TOTALLY ENCLOSED FAN MOTOR —Provides greater reliabil-
ity under adverse weather conditions and dependable perfor-
mance for many years. The permanent-split-capacitor type
motor was designed for optimum efficiency. Then, under
extreme conditions, the motor was tested and qualified to help
ensure the greatest reliability.
UNIT DESIGN —Copper tube, enhanced aluminum fin coil is
designed for optimum heat transfer. Vertical air discharge car-
ries sound and hot condenser air up and away from adjacent
patio areas and foliage. Heat pump style base pan for easy
removal of water, dirt, and leaves.
APPLICATION VERSATILITY —The 597C can be combined
with a wide variety of evaporator coils and blower packages to
provide quiet, dependable comfort. Unit can be installed on a
roof or at ground level on a slab.
EXTERNAL SERVICE VALVES —Both service valves are
brass, back seating type with sweat connections. Valves are
externally located so refrigerant tube connections can be made
quickly and easily. Each valve has a service port for ease of
checking operating refrigerant pressures.
EASY SERVICEABILITY —One access panel provides access
to electrical controls and compressor. Removal of wire dome
gives access to fan motor and removal of the top gives access
to the coil.
COMPRESSOR
PROTECTION —Each
motor is protected with internal temperature and current-sensi-
tive overloads. For improved serviceability, each compressor is
equipped with a compressor terminal plug.
SOUND HOOD —A thick, sound dampening material wrapped
around the compressor muffles operational noise.
LIMITED WARRANTY —Standard 1-year warranty on parts,
with an additional 9-year warranty on compressor.
Form No. PDS 597C.18.8
597C (60 Hz)
Sizes 018 thru 060
scroll
compressor

Advertisement

Table of Contents
loading

Summary of Contents for Bryant 597C (60 Hz

  • Page 1: Electric Air Conditioner

    SEER ratings up to 14.0 SOUND HOOD —A thick, sound dampening material wrapped when combined with specific Bryant equipment. All models are around the compressor muffles operational noise. listed with UL, c-UL, ARI, CEC, and CSA-EEV. The 597C meets LIMITED WARRANTY —Standard 1-year warranty on parts,...
  • Page 2 DIMENSIONS —2—...
  • Page 3 REQUIRED SUBCOOLING (°F) 018-F 024-F 030-F 036-F 042-F 048-G,F 060-F As an ENERGY STAR® Partner, Bryant Heating & Cooling Systems has determined that this CERTIFICATION APPLIES REGISTERED QUALITY SYSTEM product meets the ENERGY STAR® ONLY WHEN THE guidelines for energy COMPLETE SYSTEM efficiency.
  • Page 4: Specifications

    SPECIFICATIONS UNIT SIZE-SERIES 018-F 024-F 030-F 036-F 042-F 048-G/F 060-F Operating Weight (Lb) ELECTRICAL Unit Volts—Hertz—Phase 208/230—60—1 208/230—60—1 208/230—60—1 208/230—60—1 208/230—60—1 208/230—1—60 208/230—1—60 Operating Voltage Range * 187—253 187—253 187—253 187—253 187—253 187—253 187—253 Compressor— Rated Load Amps 10.0 11.4 15.0 17.9 20.0...
  • Page 5 * Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure. † If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26.
  • Page 6: Accessory Usage Guideline

    ACCESSORY USAGE GUIDELINE REQUIRED FOR REQUIRED FOR REQUIRED FOR LOW-AMBIENT LONG-LINE SEA COAST APPLICATIONS APPLICATIONS * APPLICATIONS ACCESSORY (Below 55°F) (Over 50 Ft) (Within 2 Miles) Crankcase Heater Evaporator Freeze Thermostat Winter Start Control Yes† Accumulator Compressor Start Assist Capacitor and Relay Low Ambient Controller, MotorMaster®...
  • Page 7 ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) Continued 11. Low-Ambient Controller Head pressure controller is a cycle control device activated by a temperature sensor mounted on a header tube of the outdoor coil. It is designed to cycle the outdoor fan motor in order to maintain condensing temperature within normal operating limits (approximately 100°F high and 60°F low). The control will maintain working head pressure at low-ambient temperatures down to 0°F when properly installed.
  • Page 8: Combination Ratings

    COMBINATION RATINGS SEER FACTORY- BRYANT GAS ACCESSORY UNIT SUPPLIED FURNACE OR SIZE- INDOOR TOTAL CAP. ENHANCE- STANDARD ACCESSORY SERIES SECTION BTUH MENT RATING TDR† TXV‡ CK5BA018 * 17,400 NONE — 12.00 12.00 12.00 11.05 CC5A/CD5AA018 17,400 NONE — 12.00 12.00 12.00...
  • Page 9: Combination Ratings Continued

    COMBINATION RATINGS Continued SEER FACTORY- BRYANT GAS ACCESSORY UNIT SUPPLIED FURNACE OR SIZE- INDOOR TOTAL CAP. ENHANCE- STANDARD ACCESSORY SERIES SECTION BTUH MENT RATING TDR† TXV‡ CK3BA024 23,000 13.00 — 13.00 — 12.00 CK3BA030 23,200 13.50 — 13.50 — 12.25...
  • Page 10 COMBINATION RATINGS Continued SEER FACTORY- BRYANT GAS ACCESSORY UNIT SUPPLIED FURNACE OR SIZE- INDOOR TOTAL CAP. ENHANCE- STANDARD ACCESSORY SERIES SECTION BTUH MENT RATING TDR† TXV‡ COILS + 355MAV060120 VARIABLE SPEED FURNACE CK3BA030 29,000 13.00 — 13.00 — 11.40 030-F...
  • Page 11 COMBINATION RATINGS Continued SEER FACTORY- BRYANT GAS ACCESSORY UNIT SUPPLIED FURNACE OR SIZE- INDOOR TOTAL CAP. ENHANCE- STANDARD ACCESSORY SERIES SECTION BTUH MENT RATING TDR† TXV‡ COILS + 355MAV060080 VARIABLE SPEED FURNACE CK3BA036 35,000 12.50 — 12.50 — 11.30 CK3BA042 35,000 13.00...
  • Page 12 COMBINATION RATINGS Continued SEER FACTORY- BRYANT GAS ACCESSORY UNIT SUPPLIED FURNACE OR SIZE- INDOOR TOTAL CAP. ENHANCE- STANDARD ACCESSORY SERIES SECTION BTUH MENT RATING TDR† TXV‡ COILS + 355MAV060080 VARIABLE SPEED FURNACE CK3BA042 40,500 12.50 — 12.50 — 11.00 CK3BA048 41,000 12.50...
  • Page 13 † In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. All Bryant furnaces are equipped with TDR except for the 394HAD.
  • Page 14: Detailed Cooling Capacities

    DETAILED COOLING CAPACITIES* CONDENSER ENTERING AIR TEMPERATURES °F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† System System System System System Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡...
  • Page 15 DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING AIR TEMPERATURES °F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† System System System System System Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡...
  • Page 16 DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING AIR TEMPERATURES °F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† System System System System System Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡...
  • Page 17 DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING AIR TEMPERATURES °F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† System System System System System Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡...
  • Page 18 DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING AIR TEMPERATURES °F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† System System System System System Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡...
  • Page 19 DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING AIR TEMPERATURES °F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† System System System System System Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡...
  • Page 20 DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING AIR TEMPERATURES °F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† System System System System System Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡...
  • Page 21 DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING AIR TEMPERATURES °F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† System System System System System Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡ Kw** Total Sens‡...
  • Page 22: Condenser Only Ratings

    CONDENSER ONLY RATINGS* CONDENSER ENTERING AIR TEMPERATURES °F °F 597C018-F 16.5 15.8 15.0 14.2 13.4 12.6 11.7 75.0 85.0 95.0 105.0 115.0 125.0 135.0 0.781 0.900 1.03 1.18 1.35 1.52 1.71 18.2 17.4 16.6 15.8 14.9 14.0 13.1 75.1 85.1 95.1 105.0 115.0...
  • Page 23 CONDENSER ONLY RATINGS* Continued CONDENSER ENTERING AIR TEMPERATURES °F °F 597C042-F 38.6 36.8 35.0 33.2 31.4 29.6 27.9 75.0 84.9 95.0 105.0 115.0 125.0 135.0 2.16 2.42 2.71 3.03 3.39 3.80 4.25 42.7 40.8 38.8 36.9 34.9 33.0 31.1 75.0 85.0 95.0 105.0...
  • Page 24 SYSTEM DESIGN SUMMARY 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc. 2. Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F (12.8°C). 3. Maximum outdoor operating air temperature is 125°F (51.7°C). 4.
  • Page 25: Matched System

    MATCHED SYSTEM A98599 —25—...
  • Page 26 —26—...
  • Page 27 —27—...
  • Page 28: Guide Specifications

    SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Cancels: PDS 597C.18.7 —28— © 1999 Bryant Heating & Cooling Systems, 7310 W. Morris St., Indpls., IN 46231 PRINTED IN U.S.A. Catalog No. 5259-704 11-99...

Table of Contents