UNIT
0 to 50 Ft
SIZE
Tube Length
018, 024
030, 036
3/8
042, 048
060
* For tube sets between 50 and 175 ft, consult Residential Split System Long-Line Application Guideline.
UNIT
SOUND
SIZE
LEVEL (dBA)
018
72
024
74
030
74
036
76
042
76
048
78
060
78
RECOMMENDED TUBE DIAMETERS
LIQUID TUBE DIAMETER (IN.)
Long-Line Applications*
3/8
CHECK-FLO-RATER®
UNIT SIZE-SERIES
018, E
024, E
030, E
036, E
042, E
048, E,F
060, E
* Piston listed is for any approved non-capillary tube coil combination.
Piston is shipped with outdoor unit and must be installed in an approved
indoor coil.
SOUND POWER (dBA)
OCTAVE BAND CENTER FREQUENCY (Hz)
125
250
54.5
63.0
51.5
61.0
57.0
64.0
59.0
66.0
58.0
65.0
60.0
64.0
61.5
64.5
CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE SYSTEM
IS LISTED WITH ARI
VAPOR TUBE DIAMETER (IN.)
0 to 50 Ft
Tube Length
5/8
3/4
7/8
1-1/8
PISTON*
IDENTIFICATION NO.
55
59
67
73
78
84
93
500
1000
65.5
66.0
62.5
65.5
67.0
69.0
67.0
69.5
67.5
69.0
68.5
68.5
69.0
70.0
REGISTERED QUALITY SYSTEM
—3—
Long-Line Applications*
(Maximum Diameter)
3/4
7/8
1-1/8
1-1/8
2000
4000
63.5
59.0
62.0
58.5
64.0
60.0
66.5
62.5
65.5
61.0
67.5
64.5
68.0
66.0
8000
51.5
52.5
52.5
56.0
54.0
59.5
60.5