Electrical Hazard - Stiga stig Instruction Manual

Table of Contents

Advertisement

3.3.
VERIFICATION OF THE INSTALLATION REQUIREMENTS
Below the procedures to check the necessary requirements and prepare the garden before proceeding
with the installation are described.
3.3.1. GARDEN VERIFICATION:
• Carry out a survey of the entire area for a correct detection of the state of the garden, of any
obstacles and areas to be excluded.
• Check that the lawn to be mowed is uniform, free of holes, stones or other obstacles and, if
necessary, carry out the appropriate environmental decontamination works.
NOTE: Level the ground so that no puddles form as a result of rain.
NOTE: At the first installation, the initial height of the grass must be within the operating range
of the robot lawn mower: 20-60 mm. If necessary, prepare the garden using a traditional lawn
mower.
3.3.2. CHECKS FOR THE INSTALLATION OF THE CHARGING BASE AND POWER SUPPLY:

ELECTRICAL HAZARD:

A socket must have been prepared
near the installation area to connect
it to electricity. Make sure that
connection to the power supply
network conforms to laws in force of
the Country where it is used.
ELECTRICAL HAZARD:
The circuit supplied must be protected
by a differential switch (RCD) with
an activation current not exceeding
30 mA.
Procedure:
1. Prepare a flat area at the edge of the lawn for positioning the charging base (A), preferably in the
largest portion of the garden and near an electrical outlet.
2. Make sure there is enough space to install the charging base on a straight section of the perimeter
wire (B), so that the distance of the base from any curves is at least X = 200 cm; the ground must be
perfectly flat and compact in order to avoid the deformation of the surface of the charging base.
WARNING:
The power supply cable (C) and the power supply must remain outside the
cutting area.
18
3. INSTALLATION
C
B
ELECTRICAL HAZARD:
Do not connect the power supply to
an electrical outlet if the plug or the
cable is damaged.
Do not connect or touch a damaged
cable before it is disconnected from
the power supply.
A damaged cable can lead to
contact with live parts.
A
EN

Advertisement

Table of Contents
loading

Table of Contents