Download Print this page

Accessory Usage Guideline - Bryant 550A Specifications

Deluxe 13 seer air conditioner with puron refrigerant preferred series

Advertisement

Evolution Control Deluxe 7-Day Programmable (Wall-mounted system control.)
Evolution Zone Control Deluxe Zoning 7-Day Programmable (Wall-mounted control for a
Z
multi-zone system.)
O
N
Evolution 4-Zone Damper Control Module (Wall-mounted control for a four-zone system.)
I
Evolution Smart Sensor (Optional wall control used to monitor temperature and/or fan control
N
in an individual zone.)
G
Evolution Remote Room Sensor (Monitors temperature in an individual zone.)
Evolution System Access Module (Hardware for wireless access and control via phone or
internet.)
Evolution Network Interface Module (Connects Heat Recovery or Energy Recovery Ventilators
or older two-speed outdoor models to system.)
Back Plate for Evolution Control (Decorative wall plate.)
* When applied with Bryant's Perfect Humidity™ series 355, 315 and FE Indoor Models.
† Must be installed in Dual-Fuel Evolution system applications.
ACCESSORY
Crankcase Heater
Evaporator Freeze Thermostat
Winter Start Control
Accumulator
Compressor Start Assist
Capacitor and Relay
MotorMaster® Low-Ambient Controller
or
Low-Ambient Pressure Switch
Wind Baffle
Coastal Filter
Support Feet
Liquid-Line Solenoid Valve
or
Hard Shutoff TXV
Ball Bearing Fan Motor
* For tubing line sets greater than 50 ft horizontal and/or 20 ft vertical differential, refer to Residential Split-System Long-Line Application Guideline
and Service Manual.
† Only when low-pressure switch is used.
‡ Required for MotorMaster® Control only.
ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically)
1. Ball-Bearing Fan Motor
A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.
Usage Guideline:
Required on all units when low-ambient controller (full modulation feature) or MotorMaster®—Low-Ambient Controller is installed.
2. Coastal Filter
A mesh screen inserted under the top cover and inside the base pan to protect the condenser coil from salt damage without restricting airflow.
3. Compressor Start Assist – Capacitor and Relay
Start capacitor and relay gives a "hard" boost to compressor motor at each start up.
Usage Guideline:
Required for reciprocating compressors in the following applications:
Long line
Low ambient
Hard shut off expansion valve on indoor coil
Liquid line solenoid on indoor coil
Required for scroll compressors in the following applications:
Long line
Low ambient
Suggested for all compressors in areas with a history of low voltage problems.
4. Compressor Start Assist — PTC Type
Solid state electrical device which gives a "soft" boost to the reciprocating compressor at each start-up.
Usage Guideline:
Suggested in installations with marginal power supply.
EVOLUTION™* CONTROLS
DESCRIPTION

ACCESSORY USAGE GUIDELINE

REQUIRED FOR
LOW-AMBIENT
APPLICATIONS
(Below 55°F)
Yes
Yes
Yes†
No
Yes
Yes
See Low-Ambient Instructions
No
Recommended
No
Yes‡
REQUIRED FOR
LONG-LINE
APPLICATIONS*
(Over 50 Ft)
Yes
No
No
No
Yes
No
No
No
No
See Long-Line
Application
Guideline
No
—6—
ACCESSORY
SYSTXBBUID01
SYSTXBBUIZ01
SYSTXBB4ZC01
SYSTXBBSMS01
SYSTXBBRRS01
SYSTXBBSAM01
SYSTXBBNIM01†
SYSTXXXBPU01
REQUIRED FOR
SEA COAST
APPLICATIONS
(Within 2 Miles)
No
No
No
No
No
No
No
Yes
Recommended
No
No

Advertisement