Bryant 550A Specifications page 38

Deluxe 13 seer air conditioner with puron refrigerant preferred series

Advertisement

EVAP
AIR
75
Capacity
Total
MBtuh†
Sys
CFM
EWB
Total Sens‡
kW**
57
57.89 57.89
4.31
62
59.84 53.84
4.33
1750
67
65.37 45.55
4.39
72
71.38 37.24
4.45
57
60.22 60.22
4.42
62
61.19 57.67
4.44
2000
67
66.60 48.31
4.49
72
72.67 38.92
4.56
57
62.16 62.16
4.54
62
62.34 61.20
4.54
2250
67
67.52 50.93
4.60
72
73.65 40.55
4.67
Indoor
Section
Size
CC5A/CD5AA
060
CC5A/CD5AW
060
CD5PX
060
CE3AA
060
CK3BA
060
CK5A/CK5BA
060
CK5A/CK5BT
060
CK5A/CK5BX
060
CK5PA
060
CK5PT
060
CK5PX
060
F(A,B)4BN(F,B,C)
060
FB4BNB
070
FC4CN(F,B)
060
FC4CNB
070
FE4ANB
006
FG3AAA
060
FK4DNB
006
FV4BNB
006
FX4BNB
060
COILS + 315(A,J)AV060110 VARIABLE SPEED FURNACE
CC5A/CD5AA
060
CD5PX
060
CE3AA
060
CK3BA
060
CK5A/CK5BA
060
CK5A/CK5BT
060
CK5A/CK5BX
060
CK5PA
060
CK5PT
060
CK5PX
060
COILS + 315(A,J)AV066135 VARIABLE SPEED FURNACE
CC5A/CD5AA
060
CD5PX
060
CE3AA
060
CK3BA
060
CK5A/CK5BA
060
NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240-94. If additional tubing length and/or
indoor unit is located above outdoor unit, a slight variation in capacity may occur.
† Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
‡ Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh
(245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air
per degree above 80°F (27°C). When the required data falls between the published data, interpolation may be performed.
** Total system kW is total of indoor and outdoor unit kilowatts.
†† At TVA rating indoor condition (75°F edb/63°F ewb). All other indoor air temperatures are at 80°F edb.
DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F
85
Capacity
Capacity
Total
MBtuh†
MBtuh†
Sys
Total Sens‡
kW**
Total Sens‡
550A060-H Outdoor Section With CD5PX060 Indoor Section
55.67 55.67
4.76
53.35 53.35
57.09 52.53
4.78
54.23 51.17
62.27 44.22
4.84
59.00 42.86
67.95 35.91
4.91
64.32 34.50
57.88 57.88
4.89
55.28 55.28
58.34 56.29
4.89
55.34 54.77
63.37 46.97
4.96
59.86 45.53
69.11 37.58
5.02
65.22 36.14
59.57 59.57
5.00
56.86 56.86
59.51 59.51
5.00
56.85 56.85
64.07 49.53
5.06
60.43 48.08
69.86 39.16
5.13
65.83 37.69
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Capacity
Power
0.95
0.98
0.98
1.00
1.00
1.00
0.98
0.99
0.98
0.99
0.98
0.99
0.98
0.99
1.00
0.99
0.98
0.99
0.98
0.99
1.00
0.99
0.98
1.01
1.00
1.00
0.98
1.01
1.00
1.00
1.00
0.94
0.97
0.99
1.00
0.94
1.00
0.94
1.00
1.00
0.95
0.98
0.98
0.98
0.98
0.98
0.97
0.97
0.97
0.97
0.97
0.97
0.99
0.97
0.97
0.97
0.97
0.97
0.99
0.97
0.95
0.96
0.98
0.96
0.98
0.96
0.97
0.96
0.97
0.96
95
105
Capacity
Total
Total
MBtuh†
Sys
Sys
kW**
Total Sens‡
kW**
5.27
50.80 50.80
5.83
5.28
51.12 49.67
5.84
5.34
55.44 41.38
5.89
5.41
60.36 33.01
5.96
5.39
52.49 52.49
5.95
5.39
52.48 52.48
5.95
5.45
56.10 44.02
5.99
5.52
61.05 34.63
6.06
5.50
53.93 53.93
6.06
5.50
53.92 53.92
6.06
5.55
56.59 46.55
6.09
5.62
61.56 36.15
6.16
Indoor
Section
CK5A/CK5BT
CK5A/CK5BX
CK5PA
CK5PT
CK5PX
COILS + 315(A,J)AV066155 VARIABLE SPEED FURNACE
CC5A/CD5AA
CD5PX
CE3AA
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BX
CK5PA
CK5PT
CK5PX
COILS + 355MAV060080 VARIABLE SPEED FURNACE
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5PA
CK5PT
COILS + 355MAV060100 VARIABLE SPEED FURNACE
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5PA
CK5PT
COILS + 355MAV060120 VARIABLE SPEED FURNACE
CC5A/CD5AA
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BX
CK5PA
CK5PT
CK5PX
—38—
115
Capacity
Capacity
Total
MBtuh†
MBtuh†
Sys
Total Sens‡
kW**
Total Sens‡
47.87 47.87
6.43
44.52 44.52
47.85 47.85
6.43
44.51 44.51
51.48 39.77
6.47
47.02 37.98
55.94 31.39
6.53
50.98 29.58
49.40 49.40
6.55
45.73 45.73
49.40 49.40
6.55
45.71 45.71
52.03 42.39
6.58
47.43 40.59
56.50 32.98
6.63
51.36 31.14
50.56 50.56
6.65
46.69 46.69
50.55 50.55
6.65
46.69 46.69
52.42 44.91
6.67
47.72 43.08
56.87 34.48
6.73
51.61 32.64
Cooling
Size
Capacity
060
0.97
060
0.99
060
0.97
060
0.97
060
0.99
060
0.95
060
0.98
060
0.98
060
0.97
060
0.97
060
0.97
060
0.99
060
0.97
060
0.97
060
0.99
060
0.97
060
0.97
060
0.97
060
0.97
060
0.97
060
0.97
060
0.97
060
0.97
060
0.97
060
0.97
060
0.95
060
0.97
060
0.97
060
0.97
060
0.99
060
0.97
060
0.97
060
0.99
125
Total
Sys
kW**
7.08
7.08
7.11
7.15
7.19
7.19
7.21
7.25
7.29
7.29
7.31
7.35
Power
0.96
0.96
0.96
0.96
0.96
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
1.01
1.01
1.01
1.01
1.01
1.00
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99