Download Print this page
Bryant 558F.36.1 Wiring Diagrams
Bryant 558F.36.1 Wiring Diagrams

Bryant 558F.36.1 Wiring Diagrams

Single package rooftop electric cooling units

Advertisement

Quick Links

Unit 558F
Voltage-Phase-Hertz
208/230-1-60
208/230-3-60
036,048
208/230-1-60
208/230-3-60
060
208/230-3-60, 460-3-60
072
208/230-3-60, 460-3-60
090-150
AHA
— Adjustable Heat Anticipator
AWG
— American Wire Gage
C
— Contactor, Compressor
CAP.
— Capacitor
CB
— Circuit Breaker
CC
— Cooling Compensator
COMP — Compressor Motor
D
— Diode
EC
— Enthalpy Control
ECON — Economizer
EPS
— Emergency Power Supply
(Nine-Volt Battery)
EQUIP — Equipment
ER
— Economizer Relay
FPT
— Freeze-Up Protection Thermostat
FU
— Fuse
GND
— Ground
HC
— Heater Contactor (Strip Heat)
HPS
— High-Pressure Switch
IFC
— Indoor-Fan Contactor
IFM
— Indoor-Fan Motor
IFMOVL— Indoor-Fan Motor Overload

wiring diagrams

SINGLE PACKAGE ROOFTOP
ELECTRIC COOLING
UNITS
UNIT LABEL DIAGRAM
Schematic/Component Arrangement
Schematic/Component Arrangement
460-3-60
Schematic/Component Arrangement
575-3-60
Schematic/Component Arrangement
Schematic/Component Arrangement
Schematic/Component Arrangement
460-3-60
Schematic/Component Arrangement
575-3-60
Schematic/Component Arrangement
Schematic/Component Arrangement
575-3-60
Schematic/Component Arrangement
Schematic/Component Arrangement
575-3-60
Schematic/Component Arrangement
Description
Motormaster® I Control
Motormaster II Control
Time Guard® II Device
Solid-State Enthalpy Control
Differential Enthalpy Control
EconoMi$er
EconoMi$er Sensor Wiring
Power Exhaust
IFR
— Indoor-Fan Relay
LPS
— Low-Pressure Switch
LSM
— Limit Switch (Manual Reset)
MTR
— Motor
OAT
— Outdoor-Air Thermostat
OFC
— Outdoor-Fan Contactor
OFM
— Outdoor-Fan Motor
OLR
— Overload Relay
P
— Plug
PL
— Plug Assembly
QT
— Quadruple Terminal
R
— Relay
SAT
— Supply-Air Thermostat
SEN
— Sensor
ST
— Start Thermistor
SW1
— Switch Fully Open
SW2
— Switch Fully Closed
SW3
— Switch Minimum Vent Position
SW4
— Switch Maximum Vent Position
TB
— Terminal Block
TC
— Thermostat, Cooling
Cancels: New
DIAGRAM INDEX
Type
ACCESSORY WIRING
Unit Size
036-150
036-072
090-150
036-150
036-150
036-150
036-072
036-150
036-072
LEGEND
036-150
3 to 12
WD 558F.36.1
Label Diagram
50DK508524
50DK508526
50DK508529
50DK508531
50DK508525
50DK508527
50DK508530
50DK508532
50DK508528
50DK508533
50DK508793
50DK508794
Fig. No.
13
14
15
16
17
18
19
20
21
TDR
— Time-Delay Relay
TH
— Thermostat, Heating
TRAN — Transformer
Field Splice
Marked Wire
Terminal (Marked)
Terminal (Unmarked)
Terminal Block
Splice
Splice (Marked)
Factory Wiring
Field Control Wiring
Field Power Wiring
Accessory or Optional Wiring
To indicate common potential only.
Not to represent wiring.
558F
1
/
Tons
2
11/15/00
Figure No.
1
2
3
4
5
6
7
8
9
10
11
12

Advertisement

loading

Summary of Contents for Bryant 558F.36.1

  • Page 1: Wiring Diagrams

    — Switch Fully Open — Switch Fully Closed — Switch Minimum Vent Position — Switch Maximum Vent Position — Terminal Block — Thermostat, Cooling 558F 036-150 3 to 12 Tons WD 558F.36.1 11/15/00 Label Diagram Figure No. 50DK508524 50DK508526 50DK508529 50DK508531 50DK508525 50DK508527...
  • Page 2 1. If any of the original wire furnished must be replaced, it must be replaced with Type 90 C wire or its equivalent. 2. Three-phase motors are protected under primary single-phasing conditions. 3. Thermostat: HH07AT170, 172, 174, and P272-2783 Subbase: HH93AZ176, 178, and P272-1882, 1883 1.
  • Page 13 Fig. 11 — Schematic/Component Arrangement; 558F090-150; 208/230-3-60 and 460-3-60...
  • Page 14 Fig. 12 — Schematic/Component Arrangement; 558F090-150; 575-3-60...
  • Page 15 558F036-072 LEGEND C — Contactor 558F090-150 Fig. 13 — Motormaster® I Wiring Details LEGEND — Contactor OFC — Outdoor-Fan Contactor TRAN — Transformer NOTE: Motormaster II transformer is wired for 460-v supply; it must be rewired for 208/230-v application. Be sure to insulate unused tap. Refer to color code. Fig.
  • Page 16 LEGEND — Contactor OFC — Outdoor-Fan Contactor TRAN — Transformer *The Motormaster II head pressure controller is equipped with an alternate operating mode. When this mode is selected, the controller shifts the fan cycle sequence to effectively raise the average condensing temperature approximately 20 F higher than the standard operating mode.
  • Page 17 TIME GUARD I I DEVICE HIGH EFFICIENCY 3 TO 12 TIME GUARD I I DEVICE STANDARD EFFICIENCY 3 TO 12 LEGEND — Contactor CLO — Compressor Lockout — Control Relay 24 VAC SUPPLY FROM ECONOMIZER CONTROL SECTION (RED TO TR, BRN TO TR1) TO SENSOR MOUNTED ON BACK OF CONTROL...
  • Page 18 LEGEND OAT — Outdoor-Air Thermostat ECONOMI$ER CONTROLLER -15 V +15 V REM POT Fig. 20 — EconoMi$er Sensor Wiring; 558F036-150 Fig. 19 — EconoMi$er Wiring BROWN TEMP VIOLET TEMP OUTDOOR SENSOR WHITE BROWN TEMP VIOLET RETURN TEMP WHITE SENSOR SENSOR SUPPLY AIR TEMPERATURE SENSOR PINK...
  • Page 19 TO FUSED DISCONNECT GRAY RED YEL BLU GRAY X2 X3 SECONDARY SECONDARY 230VAC 230VAC COMPRESSOR 1 CONTACTOR 230VAC 4-PIN CONNECTOR 2 x 4 IN. PLUG HANDY BOX BLACK L1 BLUE GREEN GND 230 VAC GREEN 1 PHASE Fig. 21 — Wiring Diagram for Power Exhaust System FIELD SUPPLIED WIRING BLACK...
  • Page 20 Copyright 2000 Bryant Heating & Cooling Systems CATALOG NO. 5355-810...

This manual is also suitable for:

558f036558f048558f060558f072558f090558f150