Item
Set temp.
Set the temperature.
1)
Touch [Set temp.].
2)
Set the temperature with
<Setting ranges>
y In cooling or drying mode: Between
64 °F (18 °C) and 86 °F (30 °C)
y In heating mode: Between 60 °F (16 °C)
and 86 °F (30 °C)
y Automatic: Between 62 °F (17 °C) and
80 °F (27 °C)
Fan SPD
Set the strength of the fan.
1)
Touch [Fan SPD].
2)
Select the fan speed (
(mid),
Flap
Set the direction of the airflow.
1)
Touch [Flap].
2)
Set the flap to the desired position (
(F1),
(F2),
(Swing)).
Touch
at the desired position.
y Heating, fan, and automatic (heating)
can be adjusted in 5 steps and cooling
and dry can be adjusted in 3 steps.
y You can set either
model does not support airflow direction
settings.
Prohibitn.*
Set whether to allow or prohibit use of the local
remote controller.
1)
Touch [Prohibitn.].
2)
Use
"Prhbt1", "Prhbt2", "Prhbt3", or "Prhbt4".
Accept: Allows operations with the remote
controller.
Prhbt1 to Prhbt4: Operations on the
remote controller are restricted.
Eco
Enable or disable energy saving operation.
1)
Touch [Eco].
2)
Select "Valid" or "Invl".
Enable or disable ECONAVI setting.
1)
Touch
2)
Select "Valid" or "Invl".
* Example of prohibiting or enabling remote controller use (factory
setting)
ON/OFF
Mode
Set temp.
Accept
Prhbt1
Prhbt2
Prhbt3
Prhbt4
: Operation and setting with the remote controller is possible
: Operation and setting with the remote controller is not possible
Explanation
and
.
(high),
(low),
(automatic)).
(F3),
(F4),
(F5),
during the swing to stop the flap
or
if the
to select from "Accept",
.
Fan
Flap
Eco
SPD
6
Touch [Transmit].
The settings are registered and the "Settings" dialogue
z
closes.
To cancel the settings, touch [Cancel].
z
Note
y Touch
(or
) at the upper value (or lower value) of the
set temperature and the set value becomes a blank (no setting).
Make the setting blank when you want no setting.
Furthermore, touch
(or
value) is displayed.
For example:
If upper value 86 °F (30 °C)
and lower value 64 °F
(18 °C) (cooling)
y Displays on the intelligent controller and the flap positions of the
4-way ceiling cassette type
1) When the flaps are static
Display on the intelligent
controller
2) When flaps are swinging
Display on the intelligent
controller
6
) and the upper value (or lower
66 °F (19 °C)
64 °F (18 °C) (lower limit value)
(blank)
86 °F (30 °C) (upper limit value)
84 °F (29 °C)
Flap position on the actual unit
Flap position on the actual unit
11

Advertisement

Table of Contents
loading

Table of Contents