Components
Door switch
Outer Broil heater
Inner Broil heater
Convection heater
Test procedures
1. Refer to page 3-26 for the servicing procedure
2. Measure the resistance
(Multiple meter scale: R x 1000)
1. Refer to page 3-22 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale : R x 1)
1. Refer to page 3-23 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale : R x 1)
1. Refer to page 3-24 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale : R x 1)
4-3
Results
Door latch
Door latch
open
Locked
Continuity
Infinite
Normal: Approximately
23 Ω ± 10%
If not replace
NOTE: Ω Value was tested
at room temperature
(77 F / 25 ˚C)
Be careful the element is
sensitive to temperature.
Normal: Approximately
49 Ω ± 10%
If not replace
NOTE: Ω Value was tested
at room temperature
(77 F / 25 ˚C)
Be careful the element is
sensitive to temperature.
Normal: Approximately
22 Ω ± 10%
If not replace
NOTE: Ω Value was tested
at room temperature
(77 F / 25 ˚C)
Be careful the element is
sensitive to temperature.