6
Auto Width Adjust Conveyor Setup

General Conveyor Checks

6-12
In order to check the clamps, stops and sensors, access to the
interior of the machine is required. The MAINT. SWITCH is used
to enable Maintenance mode for such checks. In Maintenance
mode, no power or control is given to the gantry or conveyor
belt motors, to safeguard personnel carrying out maintenance
and calibration on the system.
1
Remove any boards from the conveyor, and make sure the
sj5000 software is running.
Turn the MAINT. SWITCH clockwise to the ON position and
2
push the E-Stop button (the sequence is not important).
3
Open the front access door.
In Maintenance mode, use the Up and Down buttons in the
4
software to control the movement of the clamps and stops.