CONTINUITY INSPECTION
Remove the generator end cover (Base shop manual:
page 5-2).
SH, SKH type:
Disconnect main winding terminals (
and exciter 3P connector
LDH type:
Disconnect the main winding terminals (
and
Measure the resistance between the stator side
terminals according to the table below.
SH, SKH type
Main winding terminal
LDH type
Main winding terminal
.
) and exciter 3P connector
Resistance (Ω)
(at 20 °C/68 °F)
(Red) –
(Blue)
Resistance (Ω)
(at 20 °C/68 °F)
(Red) –
(White)
(Blue) –
(White)
GENERATOR/CHARGING SYSTEM
SH, SKH type:
and
)
,
,
.
0.1 - 0.3
LDH type:
0.05 - 0.2
8-13