Infinite Switch; Thermostat - Henny Penny CW-216 Technical Manual

Display counter warmer
Hide thumbs Also See for CW-216:
Table of Contents

Advertisement

2-12. INFINITE SWITCH

2-13. THERMOSTAT

305
1. Remove electrical power supplied to the cabinet.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the control side end panel.
3. Remove the electrical wires from the switch.
4. Remove the switch knob by pulling it off.
5. Remove the nut from the control panel side of the switch
and remove the switch.
6. Install a new switch in reverse order.
Step 3
Do not connect a "hot" wire to termimal "P" on the
infinite switch, or damage to the switch will result.
7. Replace the end panel.
8. Turn on the power supply at the breaker box.
1. Remove electrical power supplied to the cabinet.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the control side end panel.
3. Remove the electrical wires from the thermostat. With a test
instrument, check across the terminals of the thermostat. With
the thermostat in the 0, or OFF, position the circuit should be
open. With the thermostat set at the maximum setting the circuit
should be closed. If the thermostat checks defective, replace it
Step 3
by continuing with this procedure.
Model CW-216/CW-114
2-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cw-114

Table of Contents