Safety equipment
6.7 Stop switch – resistance
measurement
Clean the mating surfaces and check the resis-
tance as follows:
Measure the resistance by connecting a multimeter
to the ignition coil. NOTE! The switch must be in
the "on" (A) position to give the correct reading.
(see fi gure 15)
The resistance must not be higher than 0.5 Ω when
the switch is in the on position.
Fig 15
The stop switch is in the on-position when the
button is held down (A) (see fi gure 15) and in the
off-position the button is neutral (B). (See fi gure 16)
Fig 16

6.8 Assembling the choke/stop control

1
Fit a new control and new starlock washer.
2
Secure the carburettor assembly in the rubber
mounting.
21