Using the screwdriver, loosen the needle
c
clamp screw.
Lower the needle-changing tool.
d
The needle can be removed from the needle
bar.
e
Insert the new needle into the hole in the
needle-changing tool.
Insert the needle with the flat side of the needle
toward the rear of the machine.
Lift up the needle-changing tool so that the
f
fork hooks onto the needle clamp screw.
Insert the needle until it touches the needle
g
stopper, and then use the screwdriver to
tighten the needle clamp screw.
The needle is installed.
h
Lower the needle-changing tool off of the
needle.
Note
The needle-changing tool can not be used
for the twin needle.
Replacing the Needle 37