Nortel Meridian 1 Manual page 35

Table of Contents

Advertisement

Page 32 of 44
Direct Dial Inward trunk card
Trunk configuration
Supplement to 553-3011-210
Self-test
When the card is installed, the red Light Emitting Diode (LED) on the
faceplate flashes as the self-test runs. If the self-test completes successfully,
the card is automatically enabled (if it has been configured in software) and
the LED goes out. If the self-test fails, the LED will remain lit. The LED will
also remain lit if one or more units on the card become disabled while the card
is operating.
Route Data Block
Each trunk unit on the NT5K17BA DDI trunk card is attached to a route with
an associated route data block. The route data block is configured in LD 16.
Note: All prompts are defaulted except for those noted in Table 19
Table 19
LD 16 Route Data Block
Prompt
Response
REQ
NEW
TYPE
RDB
CUST
0-99
ROUT
0-127
TKTP
DID
ICOG
ICT
ACOD
XX
CNTL
YES
TIMR
EOD 19968
ICF 0
GTI 128
NEDC
ETH
FEDC
ETH
Provisional 1.3
Comments
Define a new Route Data Block
Enter customer number
Define route number
Trunk type is Direct Inward Dial
Incoming only trunk
XX=Trunk route access code
Change controls or timers
End of Dial Timer = 19968 ms
Incoming Flash Timer = 0 ms
Guard Timer Incoming = 128 ms
Near end disconnect control from
either end
Far end disconnect control from either
end
July 1993