Specifications; Stihl Hta 135 Pole Pruner; Chain Sprockets; Minimum Groove Depth Of Guide Bars - Stihl HTA 135 Instruction Manual

Hide thumbs Also See for HTA 135:
Table of Contents

Advertisement

19 Specifications

19 Specifications

19.1 STIHL HTA 135 pole pruner

– Permitted batteries:
– STIHL AP
– STIHL AR
– Weight without battery: 6.6 kg
– Max. oil tank capacity: 220 cc (0.22 l)
– Degree of electrical protection: IPX4 (protection against
splash water from any direction)
The running time is shown at www.stihl.com/battery-life.

19.2 Chain Sprockets

The following chain sprockets may be used:
– 7-tooth for 3/8" P
– 8-tooth for 1/4" P

19.3 Minimum Groove Depth of Guide Bars

The minimum groove depth depends on the pitch of the
guide bar.
– 3/8" P: 5 mm
– 1/4" P: 4 mm

19.4 STIHL AP battery

– Battery Technology: Lithium-ion
– Voltage: 36 V
– Capacity in Ah: see rating label
– Energy content in Wh: see rating label
– Weight in kg: see rating label
– Permissible temperature range for operation and storage:
-10°C to +50°C
0458-698-0121-A

19.5 Sound Values and Vibration Values

K-value (uncertainty) for sound pressure levels is 2 dB(A).
K-value for sound power levels is 2 dB(A). The K-value for
vibration levels is 2 m/s².
STIHL recommends wearing ear defenders.
– Sound pressure level L
pA
ISO 22868 for 3/8" P: 88 dB(A)
– Sound pressure level L
pA
ISO 22868 for 1/4" P: 83 dB(A)
– Sound power level L
measured according to ISO 22868
wA
for 3/8" P: 102 dB(A)
– Sound power level L
measured according to ISO 22868
wA
for 1/4" P: 96 dB(A)
Shaft fully compressed:
– Vibration level a
measured according to ISO 22867
hv
– Control handle: 4.3 m/s²
– Handle hose: 5.1 m/s²
Shaft fully extended:
– Vibration level a
measured according to ISO 22867
hv
– Control handle: 4.1 m/s²
– Handle hose: 5.6 m/s²
The vibration levels indicated were measured according to a
standardized test method and can be used as a basis for
comparing electric power tools. The vibration levels actually
occurring may vary from the values indicated, depending on
the type of application. The vibration levels indicated can be
used for an initial estimate of the vibration stress. The actual
vibration stress has to be estimated. The times when the
power tool is switched off and the times when it is switched
on but running under no load can be taken into account in
the estimate.
For information on compliance with Employers' Vibration
Directive 2002/44/EC see www.stihl.com/vib.
English
measured according to
measured according to
31

Advertisement

Table of Contents
loading

Table of Contents