Operation

To prevent accidental gun operation, always
disconnect air supply before servicing gun or anytime
gun is not in use.

Grounding

The equipment must be grounded to reduce the risk
of static sparking. Static sparking can cause fumes to
ignite or explode. Grounding provides an escape wire
for the electric current.
Follow local codes, regulations, and your proportioner
manual for detailed grounding instructions.
Spray gun: ground the spray gun through connection to
a properly grounded fluid hose and pump.

Air Hose Connection

To connect air hoses: pull back the sleeve of the
female fitting, insert the male fitting and slide the sleeve
forward to secure connection.
To disconnect air hoses: pull back the sleeve of the
female fitting and pull out the male fitting.
Pull Sleeve
F
. 8
IG
311321V

Safety Lock

High-pressure fluid from dispensing devices can
pierce skin. To help prevent serious injury from
pressurized fluid, always engage the piston safety
lock and close the material shutoff valves to avoid
accidental triggering whenever you stop spraying.
The CLOSED (SERVICE) position will not allow the gun
to discharge. The OPEN position allows the gun to
dispense. Whenever the gun is not spraying, set to
CLOSED (SERVICE) position.
To engage safety lock: push in and turn the safety lock
clockwise to place the gun in CLOSED (SERVICE)
position.
F
. 9: Safety Lock - Closed
IG
To disengage safety lock: push in and turn the safety
lock counterclockwise to place the gun in OPEN position
(red band is exposed).
Red Band
F
. 10: Safety Lock - Open
IG
Operation
CLOSED (SERVICE)
Put in safety position when not
spraying.
OPEN
Red band exposed to
spray.