Assembly; Unpacking; Changes To The Surface Protection Of The Valve; Installation Conditions - Bosch Rexroth WE6/BVP1 Series Operating Instructions Manual

Directional spool valves, direct operated, with solenoid actuation
Table of Contents

Advertisement

22/48
Mounting
Bosch Rexroth AG, WE6../.B..VP1..., RE23178-VP1-B/06.16
7 Mounting
High pressure!
Risk of injury due to parts being ejected during works on hydraulic accumulators
which have not been unloaded.
Carry out any work at the valve only after the system has been depressurized.
Unload accumulators which may have been mounted at the system.
Check the system with test pressure according to ISO 4413.
Installation and commissioning may only be carried out by specialists.

7.1 Unpacking

Falling parts!
Risk of injury! If the packaging is opened improperly, parts may fall out and cause
injuries or damage of the parts.
Put the packaging on level, bearing ground.
Only open the packaging from the top.
Dispose of the packaging in accordance with the national regulations of your
country.

7.2 Changes to the surface protection of the valve

Explosion hazard caused by changes to the valve!
Any change to the surface protection of the valve solenoid will lead to loss of the
explosion protection!
The valve solenoid must not be painted or otherwise coated with non-conductive
substances.

7.3 Installation conditions

For installing the product, always observe the environmental conditions specified
in "Data sheet 23178-VP1".
It is imperative to provide for absolute cleanliness. The valve must be protected
from dirt during installation. Contamination of the hydraulic fluid may
considerably reduce the service life of the valve.
Observe the installation position specified in "Data sheet 23178-VP1".
CAUTIOn
CAUTIOn
wARnInG

Advertisement

Table of Contents
loading

Table of Contents