Operating The Manual Override - Bosch Rexroth WE6/BVP1 Series Operating Instructions Manual

Directional spool valves, direct operated, with solenoid actuation
Table of Contents

Advertisement

34/48
Operation
Bosch Rexroth AG, WE6../.B..VP1..., RE23178-VP1-B/06.16

9.2 Operating the manual override

Danger of damage to property!
If the manual override is operated in an uncontrolled manner, there is a risk of
damage to the system!
Only operate the manual override if it is ensured that this will not trigger any
dangerous working movement of the connected actuator.
Only operate the manual override if the pressure in the tank channel of the valve
does not exceed 50 bar. Above this pressure value, the actuating force to be
applied is too large.
Do not use sharp-edged tools to operate the manual override.
The valves are equipped with a manual override. Using this manual override, the
switching function of the valve can also be triggered when the solenoid is not
energized.
The manual override is only intended for manual operation. It is not suitable for
frequently recurring manual operation.
The manual override is located on the side of the valve solenoid facing away from the
valve.
NOTICE