Advertisement

Combined Systems

Two Masters
I/O Connecting
Cable
Example 4 I/O Link Units
Optical Fiber Cable
(APF/PCF)
C200H CPU
Rack
C200H Master
C200H-RM001-PV1
2-8
Combined Systems
Example 1 Connecting Other Units to C200H Masters
C500 Slaves
22
C200H Masters
C200H-RM001-PV1
C200H CPU Rack
C200H Slave
Rack
Expansion I/O
Rack
A maximum of 512 I/O points on I/O Link Units can be connected per master, i.e.,
when the I/O Link Units are all set for 16 points each, up to 32 Units can be con-
nected to one Master on a C200H. (The C20 I/O Link Unit has no setting for the
number of I/O points and is thus limited to 32 points.)
I/O Link Unit
3G2A5-LK010-(P)E
Up to two C500 Slaves, either optical or wired, can be connected to the C200H
PC (regardless of the number of C200H Masters). C500 Slaves and C200H
Slaves can also be used in combination; however, a maximum of five Slaves can
be attached, with each C500 Slave counted as two Slaves. Any Wired Slaves
must be counted in the total. Here, Special I/O Units can be mounted to C500
Optical Fiber Cable (APF/PCF)
C200H Slave Rack
Expansion I/O Rack
I/O Connecting
Cable
Expansion I/O Rack
C1000H or C2000H CPU
Rack
C20,
K-type
or P-type
PC
C500, C1000H or C2000H
Expansion I/O Rack
Section
C20 I/O Link Unit
3G2C7-LK011-(P)E
2-8

Advertisement