ADTRAN TRACER 4106 Plan A System Manual page 49

Adtran network device system manual
Table of Contents

Advertisement

TRACER 4106/4206 System Manual
Delivered
Bandwidth
4xT1
2xT1
1xT1
Both ends of the TRACER link must be set to the same number of active T1 ports. The TRACER 4106/4206
comes factory programmed with
When changing active T1 ports on installed links, change the remote end first. If the local
end is changed first, remote configuration capability is lost. In the event the local end is
changed first and the link is dropped, reset the local end to the previous setting to restore
the link.
>TRACER S
YSTEM
Configures the modem control leads on the RS-232 port (terminal interface located on the rear panel of the
unit). Set
M
C
ODEM
ONTROL
Setting
M
C
ODEM
ONTROL
data to be sent to the VT100 continuously.
terminal is in use. The TRACER 4106/4206 comes factory programmed with
.
D
ISABLED
Press <Ctrl+Z> three times from the terminal interface to disable
the modem control leads are active.
>TRACER S
YSTEM
Causes the TRACER 4106/4206 to de-assert Clear To Send (CTS) and DSR for a time greater than 20 msec.
This signals the modem to disconnect the analog connection. Hangup-On-DTR-Drop may need to be
explicitly enabled on some modems. If
close the current session and return to the TRACER System Status menu page and wait for password input.
>TRACER S
YSTEM
Configures password protection for the VT100 terminal interface. Password protection for the
TRACER 4106/4206 requires password input from the TRACER 4106/4206 System Status menu page when
connecting to the unit. When configured for password protection, the TRACER 4106/4206 closes any
terminal session that remains inactive for more than 10 minutes. The TRACER 4106/4206 comes factory
programmed with
P
ASSWORD
>TRACER S
YSTEM
Sets the password for password protection of the TRACER 4106/4206 VT100 terminal interface. Enter up to
8 alphanumeric characters. The system password is case sensitive.
The default password for the TRACER 4106/4206 is tracer.
612804206L2-1A
Table 1. Receiver Sensitivity for the TRACER 4106/4206
Receiver Sensitivity
TRACER 4106
-93 dBm
-96 dBm
-98 dBm
A
T1 P
CTIVE
ORTS
O
> M
C
PTIONS
ODEM
to
E
when connecting the unit to a modem (using a null modem adapter).
NABLED
to
D
prevents the TRACER 4106/4206 from monitoring DCD and enables
ISABLED
M
ODEM
O
> M
C
PTIONS
ODEM
P
ASSWORD
O
> P
PTIONS
ASSWORD
set to
E
D
NABLE
ISABLED
O
> P
PTIONS
ASSWORD
© 2004 ADTRAN, Inc.
TRACER 4206
-90 dBm
-93 dBm
-95 dBm
set to
4
T1
.
X
ONTROL
must be set to
C
ONTROL
(L
ONNECTION
OGOUT
is
P
E
ROTECTION
NABLED
E
NABLE
.
Section 5 User Interface Guide
Active
T1 Ports
A – D
A, B
A
when the VT100
D
ISABLED
set to
M
C
ODEM
ONTROL
M
C
ODEM
ONTROL
)
, this menu also causes the unit to
when
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tracer 4206 plan aTracer 4106Tracer 4206

Table of Contents