Download Print this page

Brother HL-960 Series User Manual page 253

Brother hl-960: users manual

Advertisement

Bar Code Human Readable Line On or Off
n = "r0" or "R0"
Human readable line OFF
n = "r1" or "R1"
Human readable line ON
Default: Human readable line ON
(1) "T5" or "t5"
(2) "T6" or "t6"
(3) "T130" or "t130"
(4) "T131" or "t131"
Default: Human readable line OFF
All others
This parameter specifies whether or not the printer prints
the human readable line below the bar code. Human
readable characters are always printed with OCR-B font of
10 pitch and all the current character style enhancements
are masked. Note that the default setting is subject to the
bar code mode selected by "t" or "T".
Quiet Zone
n = "onnn" or "Onnn" (nnn = 0
Quiet Zone is the space on both side of the bar codes. Its
width can be specified using the units which are set by the
"u" of "U" parameter. (For the description of "u" or "U"
parameter, see the next section.) The default setting of
Quiet Zone width is 1 inch.
Bar Code, Expanded Character Unit, Line Block Drawing &
Box Drawing
n = "u0" or "U0" Millimeters (default)
n = "u1" or "U1" 1/10"
n = "u2" or "U2" 1/100"
n = "u3" or "U3" 1/12"
n = "u4" or "U4" 1/120"
n = "u5" or "U5" 1/10 Millimeters
n = "u6" or "U6" 1/300"
n = "u7" or "U7" 1/720"
This parameter specifies the measurement units of X-axis
offset, Y-axis offset, and bar code height.
~
32767)
APPENDICES
Appendix–61

Advertisement

loading