Siemens SIMATIC IOT2000 Series Setting Up

Siemens SIMATIC IOT2000 Series Setting Up

Hide thumbs Also See for SIMATIC IOT2000 Series:

Advertisement

Maratona Informatica
SFIDA PROPOSTA DA:
FINCANTIERI
Industrial BOT 4.0
Creazione di un sistma di monitoraggio per PLC (sistemi ICS) basato su
sistema IoT 2040 che permette l'interazione tramite chatbot o comandi
vocali. Verifica del traffico per garantire non siano presenti attacchi
informatici sui sistemi.
COMPETENZE DI BASE RICHIESTE
Networking, programmazione, scripting, analisi dei dati
COSA VIENE FORNITO
IoT2040, manualistica, switch di rete
COSA OCCORRE PORTARE
Snort o software per analisi di rete, ambienti di sviluppo, QRadar (community
edition), Eclipse/NodeRed/NodeJS con SDK Siemens open source per
IoT2040. Software SSH, versioni free doi Alexa o Google Home, Whatson
ALLEGATI/LINK UTILI
SIMATIC IOT2040 – the intelligent gateway for industrial IoT solutions
https://youtu.be/xtruhSQcxrs
SIMATIC IOT2020, SIMATIC IOT2040 Manual.
https://support.industry.siemens.com/cs/ww/en/view/109741658
SIMATIC IOT2000 SD-Card example image
https://support.industry.siemens.com/cs/ww/en/view/109741799
SIMATIC IOT2000 Eclipse Plugin
https://support.industry.siemens.com/cs/ww/en/view/109744106
SIMATIC IOT2000 forum
https://support.industry.siemens.com/tf/ww/en/conf/60/
IOT2000 Starter Guide and useful information
https://support.industry.siemens.com/tf/ww/en/posts/iot2000-starter-guide-and-
useful-information/155652/?page=0&pageSize=10
Setting up the SIMATIC IOT2000
https://support.industry.siemens.com/tf/ww/en/posts/setting-up-the-simatic-
iot2000/155642/?page=0&pageSize=10
Video "How To Set Up A Siemens Simatic IoT2040"
https://youtu.be/e7Q1Sk9Dk4A
SFIDA RIVOLTA A CATEGORIE
Senior e Junior
NOTE
La gara è a numero chiuso (saranno ammessi i primi 5 gruppi che si prenoteranno
il giorno della sfida). In caso di mancata ammissione, si consiglia di prepararsi in
anticipo ad affrontare una delle altre gare disponibili.
Iscrizione
obbligatoria su
www.uniud.it/careercenter
IV edizione
28 maggio
1 giugno
2019

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC IOT2000 Series

  • Page 1 Setting up the SIMATIC IOT2000 https://support.industry.siemens.com/tf/ww/en/posts/setting-up-the-simatic- iot2000/155642/?page=0&pageSize=10 Video “How To Set Up A Siemens Simatic IoT2040“ https://youtu.be/e7Q1Sk9Dk4A SFIDA RIVOLTA A CATEGORIE Senior e Junior NOTE La gara è a numero chiuso (saranno ammessi i primi 5 gruppi che si prenoteranno il giorno della sfida).
  • Page 2 Setting up  08/2017 Setting up the SIMATIC IOT2000 SIMATIC IOT2020, SIMATIC IOT2040...
  • Page 3: Warranty And Liability

    Application Examples at any time without prior notice. If there are any deviations between the recommendations provided in these Application Examples and other Siemens publications – e.g. Catalogs – the contents of the other documents have priority. We do not accept any liability for the information contained in this document.
  • Page 4: Table Of Contents

    Table of contents Table of contents Warranty and liability ....................2 Task ........................4 Overview....................4 Requirements ..................... 5 Required Hardware ................5 Required Software ................9 Operating ......................10 Installing the SD-Card Example Image ..........10 First Commissioning of the SIMATIC IOT2000 ........15 3.2.1 Remote access with Putty SSH Connection ........
  • Page 5: Task

    Task Overview Introduction This Setting Up shows how to set up the SIMATIC IOT2000 with a SD-Card image provided through the Siemens Industry Online Support. Goals After working through this document you know how to  Get remote access to the SIMATIC IOT2000 ...
  • Page 6: Requirements

    2 Requirements Requirements Required Hardware This chapter contains the hardware required for this Setting up. SIMATIC IOT2000 Two different versions of the SIMATIC IOT2000 are available. The hardware of both versions is described in this document. However, this Setting Up will only use the SIMATIC IOT2020 as basis for all examples.
  • Page 7 2 Requirements Figure 2-1 Table 2-1 Description Aperture for wall-mounting Designation for integration of antennas Connection for Power Supply 5 LED’s, 1 programmable USER LED Left cap Right cap Aperture to lock the right cap RESET button for the CPU USER button Ethernet Interface 10/100 Mbps USB Typ Mini-B...
  • Page 8 2 Requirements SIMATIC IOT2040 Hardware Overview:  Intel Quark® x1020  1 GB RAM  2 Ethernet Interfaces  2 RS232/485 interfaces  Battery buffered RTC Interface Overview: Figure 2-2 IOT2000 Setting Up Version 2.1, 08/2017...
  • Page 9 2 Requirements Table 2-1 Description Aperture for wall-mounting Designation for integration of antennas Connection for Power Supply COM-Interfaces (RS232/485) 5 LED’s, 1 programmable USER LED Left cap Right cap Aperture to lock the right cap RESET button for the CPU USER button Ethernet Interface 10/100 Mbps Ethernet Interface 10/100 Mbps...
  • Page 10: Required Software

    To use the full functionality of the SIMATIC IOT2000 a SD-Card Example Image with a Yocto Linux Operating System is necessary to be installed. This Image is provided through the Siemens Industry Online Support. It can be downloaded here. PuTTY To get remote access to the SIMATIC IOT2000 software is required.
  • Page 11: Operating

    The first step to work with the SIMATIC IOT2000 is to set up a Micro-SD Card with the Image provided through the Siemens Industry Online Support. The following table shows the required steps to transfer the SD-Card Image to a Micro-SD Card.
  • Page 12 3 Operating Action Select “*.*” in the right bottom corner Then select the “iot2000-example-image-iot2000.wic” file in the retrieved SD Card Image folder Select the drive letter of your SD Card Click the “Write” button IOT2000 Setting Up Version 2.1, 08/2017...
  • Page 13 3 Operating Action Confirm the warning message NOTE: All data will be deleted You will receive a success message if the transfer is done Right click on “Safely Remove Hardware and Eject Media” Choose the SD Card IOT2000 Setting Up Version 2.1, 08/2017...
  • Page 14 3 Operating Action Insert the µSD-Card into the µSD-Card Slot of the SIMATIC IOT2000 as follows: Slide the locking down Open the locking Insert the µSD-Card IOT2000 Setting Up Version 2.1, 08/2017...
  • Page 15 3 Operating Action Close the locking and slide it up IOT2000 Setting Up Version 2.1, 08/2017...
  • Page 16: First Commissioning Of The Simatic Iot2000

    3 Operating First Commissioning of the SIMATIC IOT2000 Ethernet cable The following table shows how to connect the SIMATIC IOT2000 and the engineering station with an Ethernet cable. Table 3-2 Action Connect one end of the Ethernet cable to an Ethernet-Port of the Engineering Station Connect the other end of the Ethernet cable to the Ethernet-Port X1P1 of the SIMATIC IOT2000.
  • Page 17 3 Operating NOTE The SIMATIC IOT2000 has a static IP address by default. This address is 192.168.200.1. The Engineering Station has to be in the same subnet as the SIMATIC IOT2000 to establish a SSH connection! The first boot may last a few minutes –up to 5 – because the filesystem is NOTE resized automatically.
  • Page 18 3 Operating Action Click on “Open” button for opening the communication to the SIMATIC IOT2000 via SSH. Connecting the first time via SSH a Warning dialog will appear. It is necessary to update the SSH key. Press the “Yes” button. IOT2000 Setting Up Version 2.1, 08/2017...
  • Page 19 3 Operating Action If once confirmed a login dialog appears Type “root” and press the Enter key The login was successful. Note: There is no password set per default. IOT2000 Setting Up Version 2.1, 08/2017...
  • Page 20 3 Operating Action Set a password for the login “root” because of security issues: Type in “passwd” Set a new password (input is hidden) Confirm the password (input is hidden) Now a few Linux commands can be tested. For example “cd /” to get in the file system and “ls” to list the folders in the current directory IOT2000 Setting Up Version 2.1,...
  • Page 21: Change Ip Address

    3 Operating 3.2.2 Change IP Address In the default settings of the SIMATIC IOT2000’s Image, the IP address is set to 192.168.200.1. Thus, if another static IP address or a DHCP address is required, this can be set with the iot2000setup tool The following table displays the procedure for configuring the IP address settings.
  • Page 22 3 Operating Action Change the static IP address of your interface here, if required. If a DHCP address is required, write “dhcp” to your interface If you want to change the netmask you have to edit the file “interfaces” in the directory “/etc/network”...
  • Page 23: Create New Directory On The Simatic Iot2000

    3 Operating 3.2.3 Create new directory on the SIMATIC IOT2000 The default storage path for scripts, created with the Eclipse IDE, on the SIMATIC IOT2000 is the directory “tmp”. The files present in this directory, will be automatically deleted after a reset or power failure of the SIMATIC IOT2000. In order to avoid the loss of scripts, a new directory can be created where the files will be stored.
  • Page 24 3 Operating Action The created folder is now present in the directory “/home”. IOT2000 Setting Up Version 2.1, 08/2017...
  • Page 25: Checklist

    4 Checklist Checklist This chapter contains a Checklist which summarizes all important steps in this Setting up. Table 4-1 Action Download the software listed Write the image to the µSD Card Insert the µSD-Card to the SIMATIC IOT2000 Connect the Ethernet cable Connect the Power Supply Establish a SSH with PuTTY Change IP-Address...
  • Page 26: Related Links

    5 Related links Related links Table 5-1 Topic SIMATIC IOT2000 forum www.siemens.com/iot2000-forum Download SD-Card Example Image https://support.industry.siemens.com/cs/ww/en/view/109741799 SIMATIC IOT2000 Getting Started https://support.industry.siemens.com/tf/ww/en/posts/155643/ Operating Instructions https://support.industry.siemens.com/cs/document/109741658/simatic-iot2020- simatic-iot2040?dti=0&lc=en-WW History Table 6-1 Version Date Modifications V1.0 09/2016 First version Added chapter “Resize the SD card partition”...
  • Page 27 The intelligent gateway for industrial IOT solutions SIMATIC IOT2040 siemens.com/iot2000 With advancing digitalization, there continues to be steady progress in networking between production and office IT. Performance. Openness. Expandability. Production data is collected and analyzed in the cloud or in SIMATIC IOT2040 at a glance the management system to optimize production.
  • Page 28 Subject to changes and errors. The information given Published by Article-No. DFFA-B10236-00-7600 PDF in this document only contains general descriptions Siemens AG 2016 Printed in Germany and/or performance features which may not always Digital Factory Dispo 06303 specifically reflect those described, or which may P.O.

This manual is also suitable for:

Simatic iot2020Simatic iot2040

Table of Contents