Siemens 5WG1 201-2DBx3 Series Technical Product Information
Siemens 5WG1 201-2DBx3 Series Technical Product Information

Siemens 5WG1 201-2DBx3 Series Technical Product Information

Gamma arina touch sensor

Advertisement

Gamma arina touch sensor
Touch sensor, single
UP201/x2, without status LED and with orientation LED
UP201/x3, with status LED and orientation LED
Touch sensor, double
UP202/x2, without status LED and with orientation LED
UP202/x3, with status LED and orientation LED
Touch sensor, quadruple UP203/x2, without status LED and with orientation LED
UP203/x3, with status LED and orientation LED
UP203/x4, with status LED, orientation LED, scene controller and room temperature sensor
UP203/x5, with status LED, orientation LED, scene controller, and IR receiver decoder
Product
without status LED and with ori-
entation LED
with status LED and orientation
LED
with status LED, orientation LED,
scene controller, and room
temperature sensor
with status LED, orientation LED,
scene controller and IR receiver
decoder
F3
F4
F1
F5
Figure 1: Mounting touch sensor arina
Product and Applications Description
The touch sensors for the Gamma arina have one, two or
four vertically arranged pairs of sensitive touch areas. A
paper foil is placed in the middle between these sensitive
touch areas for labeling. The paper foil is
These types of touch sensors are available:
• Touch sensor single, double and quadruple, with one
orientation LED, without status LED.
• Touch sensor single, double and quadruple, with one
orientation LED and with one status LED per touch
area.
• Touch sensor quadruple, with one orientation LED, one
status LED per touch area, scene controller, and room
temperature sensor.
UP 20x, UP 28x/3 and UP 28x/5
Siemens Building Technologies
Touch sensor, single
ivory white
5WG1 201-2DB12
champagne
5WG1 201-2DB32
ivory white
5WG1 201-2DB13
champagne
5WG1 201-2DB33
ivory white
champagne
ivory white
champagne
F2
E6
replaceable.
Subject to change without further notice
Technical product information
Touch sensor, double
5WG1 202-2DB12
5WG1 202-2DB32
5WG1 202-2DB13
5WG1 202-2DB33
E6
Labelling field
F1
Mounting frame
F2
Mounting screws
F3
Back housing
F4
Front housing
F5
Programming button
• Touch sensor quadruple, with one orientation LED, one
status LED per touch area and IR receiver-decoder.
The touch sensors are mounted together with the
mounting frame DELTA® arina onto a 86 mm x 86 mm
conduit box.
The mounting frame is not included and therefore have
to be ordered separately (see current catalog).
Update: http://www.siemens.com/gamma
Gamma instabus
June 2014
5WG1 201-2DBx2
5WG1 201-2DBx3
5WG1 202-2DBx2
5WG1 202-2DBx3
5WG1 203-2DBx2
5WG1 203-2DBx3
5WG1 203-2DBx4
5WG1 203-2DBx5
Touch sensor, quadruple
5WG1 203-2DB12
5WG1 203-2DB32
5WG1 203-2DB13
5WG1 203-2DB33
5WG1 203-2DB14
5WG1 203-2DB34
5WG1 203-2DB15
5WG1 203-2DB35
Technical product information
2.16.1.13/1

Advertisement

Table of Contents
loading

Summary of Contents for Siemens 5WG1 201-2DBx3 Series

  • Page 1 • Touch sensor quadruple, with one orientation LED, one status LED per touch area, scene controller, and room temperature sensor. UP 20x, UP 28x/3 and UP 28x/5 Technical product information Siemens Building Technologies Subject to change without further notice Update: http://www.siemens.com/gamma 2.16.1.13/1...
  • Page 2: Common Functions

    LED for each of up to three value ranges • Dual-touch-area control of solar protection (blinds, respectively to either roller shades) o on Technical product information UP 20x, UP 28x/3 and UP 28x/5 Update: http://www.siemens.com/gamma Subject to change without further notice Siemens Building Technologies 2.16.1.13/2...
  • Page 3 “Delete scene memory after bus voltage recovery” is set to “Yes”. UP 20x, UP 28x/3 and UP 28x/5 Technical product information Siemens Building Technologies Subject to change without further notice Update: http://www.siemens.com/gamma 2.16.1.13/3...
  • Page 4: Installation Notes

    10 seconds for the programming mode. This is indicated by briefly flashing the programming LED. Technical product information UP 20x, UP 28x/3 and UP 28x/5 Update: http://www.siemens.com/gamma Subject to change without further notice Siemens Building Technologies 2.16.1.13/4...
  • Page 5: Technical Data

    • Bus: safety extra-low voltage SELV DC 24 V • Device complies with: EN50491-3, IEC 60669-2-1, and IEC 60669-2-5 UP 20x, UP 28x/3 and UP 28x/5 Technical product information Siemens Building Technologies Subject to change without further notice Update: http://www.siemens.com/gamma 2.16.1.13/5...
  • Page 6: Installation And Wiring

    Labelling field (length: 82 ± 0.15mm, width: 18.35 ± 0.1mm, thickness: < 0.2 mm) IR receiver hole (UP 203/x5 only) Technical product information UP 20x, UP 28x/3 and UP 28x/5 Update: http://www.siemens.com/gamma Subject to change without further notice Siemens Building Technologies 2.16.1.13/6...
  • Page 7 Please be noted the polarity of bus connection with mark on housing. Figure 5: Connect KNX connector Back housing Front housing KNX connector KNX line UP 20x, UP 28x/3 and UP 28x/5 Technical product information Siemens Building Technologies Subject to change without further notice Update: http://www.siemens.com/gamma 2.16.1.13/7...
  • Page 8: Address Assignment

    LED is not invisible when turns off. Figure 8: Remove the KNX connector Mounting frame Back housing Front housing KNX connector Technical product information UP 20x, UP 28x/3 and UP 28x/5 Update: http://www.siemens.com/gamma Subject to change without further notice Siemens Building Technologies 2.16.1.13/8...
  • Page 9: Dimension Drawing

    Dimensions in mm client. • Any faulty device is to be sent together with a return delivery note of the local Siemens office. • If you have further questions concerning the product please contact our technical support.  +86 (10) 4006306090 ...

Table of Contents