Measuring timing slips

11 Connect the HST-3000 to the test access point
shows a PMP connection):
– Connect the HST E1 RX/TX1 jack to the access point
– Connect the HST E1 RX/TX2 jack to the access point
Network
Figure 6
Monitor connections
12 Press the Home navigation key, and then restart the test.
13 To view other results, see
page
39.
You have finished monitoring the circuit.
The HST-3000 allows you to monitor the timing between two
E1 signals for timing slips. For example, you can check
customer premises equipment against a master clock at the
central office, or you can compare two lines of network equip-
ment. The HST-3000 measures the difference, in bits per
second (bit/s), between the opposite receiver (Rx) or the
external 2M Reference clock.
HST-3000 E1 Testing User's Guide
RX/TX2
RX/TX1
HST-3000
PMP
Line 1
"Viewing test results" on
Chapter 2 E1 testing

Measuring timing slips

(Figure 6
CPE
Line 2
25