Nokia RH-37 Series Rf Troubleshooting Instructions page 37

Transceivers
Table of Contents

Advertisement

Nokia Customer Care
Setup with Phoenix:
Band: GSM 1800
Mode: RX Continuous
Channel: 700
Spectrum analyzer
VCO out (G7500)
f
= 3685.6 MHz
VCO
Vc of VCO = 2.1..2.6V
No
Spectrum analyzer
VCO out (G7500)
Some signal 3 - 4.4 GHz
Yes
Oscilloscope
VCO tuning voltage
Vc of VCO = 0V
Yes
Oscilloscope
PLL supply
(VR1=4.7V, VR5=2.78V)
It is important to note that the power supply VR3 of the VCTCXO is only switched off in
the so called 'Deep Sleep Mode' and the power supply VR7 of the VCO (G7500) is
switched off in so called 'Sleep Mode'.
Issue 1 07/04
Yes
PLL Block is functional
No
Oscilloscope
VCO supply
(VR7 = 2.78V)
No
Oscilloscope
Check RFBus signals
RFBusClk, RFBusData,
RFBusEn1 ok?
Yes
No
Nokia Corporation
6(b) - RF Troubleshooting Instructions
Check R7503 and T7500.
Change VCO G7500
Yes
Check supply filter components:
C2203, R7500, C7500, C7501
No
Check UEM.
Change RF ASIC N7500
Yes
Check baseband part.
No
Check loop filter components:
C7502, C7503, C7504, R7501, R7502
Short circuit to ground?
RF ASIC N7500 could be defective.
Check supply filter components:
C2232, C299, C7516, C7517, C7518
Check UEM.
RH-37
Synthesizer
Fault Finding Tree
part 2
Page 37

Advertisement

Table of Contents
loading

Table of Contents