RH-37
6(b) - RF Troubleshooting Instructions
Select faulty band in Phoenix and continue measurements on dedicated Rx part.
Phoenix:
open SNR Measurement
Meas. Mode:
Fast SNR
Press Measure .
Signal Generator:
Level:
–92dBm
Frequency:
calculated from Phoenix
Phoenix:
SNR measurement ok?
(SNR > 18.37dB)?
No
Phoenix:
Phone:
local mode
RF Controls :
Active Unit:
Rx
Op. Mode:
Continuous
Rx/Tx channel:
default (mid)
AGC:
14
Signal Generator:
To be tuned that input power at spectrum
analyser:
–60dBm
power at probe:
Pref =approx. -63dBm)
Frequency:
calculated from Phoenix
offset: 67.71kHz
Spectrum Analyzer:
Center Freq:
calculated from Phoenix
RBW
20kHz
Check Rx SAW filter and matching
network of selected band:
GSM900
TPs: INM_G_RX / INP_G_RX
both output levels > Pref -3.5dB ?
GSM1800
TPs: INM_D_RX / INP_D_RX
both output levels > Pref -6dB ?
Yes
Page 16
Single band fault finding
Front end is ok.
Yes
Phoenix:
Phone:
RF Controls :
Active Unit:
Op. Mode:
Rx/Tx channel:
AGC:
Signal Generator:
Level:
Frequency:
Continue with Rx Fault Finding part 6.
1)
Change Rx SAW filters (Z7802,
Z7803) or component(s) of
No
matching network depending on
selected band
Nokia Corporation
Nokia Customer Care
local mode
Rx
Continuous
default (mid)
10
–60dBm
calculated from Phoenix
offset: 67.71kHz
1)
Note
:
RF levels are dependent on RF probe and have to be validated
with a known good sample.
Receiver
Fault Finding Tree
part 7
Receiver
Fault Finding Tree
part 8
Issue 1 07/04