Nokia 3806 Service Manual page 143

Mobile terminal
Hide thumbs Also See for 3806:
Table of Contents

Advertisement

RM-583
RF Description and Troubleshooting
TX path faults
No
Measure
DC
test
1@table 1, is it 3.8V?
Yes
Measure
DC
test
2@table 1, is it high?
Yes
Measure
DC
test
3@table 1, is it high?
Yes
No
Measure RF test point 1@
table 2, is it ok?
Yes
Measure RF test point 2@
table 2, is it ok?
Yes
Measure RF test point 3@
table 1, is it OK?
No
Yes
Measure RF test point 4@
table 2, is it ok?
Yes
Measure RF test point 5@
table 2, is it ok?
Yes
TX troubleshooting finished
Issue 1
No
point
Check Power supply
Is it 3.8V?
No
point
Reheat solder joints
Of QSC1110
No
point
Reheat solder joints
Of QSC1110
No
Reheat solder joints of
L312,,C319, C320
No
No
Reheat solder joints
of C253
No
Reheat solder joints
of U201
No
Reheat solder joints
Of U103
No
Reheat solder joints
Of C103
COMPANY CONFIDENTIAL
Copyright © 2009 Nokia. All rights reserved.
Set its output to 3.8V
No
Change U202(PA)
No
Reheat solder joints
Of S101
Page 7-11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rm-583