4. PROVISIONING

All provisioning will be handled through the SCU
communication link, either through the menu access or
SNMP. There are no onboard DIP switches or jumpers.
The unit will retain provisioning data in a nonvolatile
memory device in case of a loss of power to the module.
Total Access 3000 system management and provi-
sioning is facilitated by a series of intuitive menus that
are accessible on a computer screen. Connecting either
a VT100 terminal or a PC emulating a VT100 terminal
to the craft interface on the SCU front panel allows
access to the menus and management features of the
Total Access 3000.
The front craft access port for the Total Access 3000
system is located on the front panel of the SCU and is a
DB-9 connector. Access can also be made to the Total
Access 3000 chassis from the backplane through the
port labeled
(J31). It is a DB-25 connector, and
ADMIN
is located on the upper right corner of the backplane.
NOTE
Connecting to the Total Access 3000 chassis
from the front craft port on the SCU requires a
straight serial data cable. Connection to the
Total Access 3000 chassis via the rear
connector on the backplane requires the use of
a null modem cable, because that port is
configured for a modem and expects to see
DCE equipment.
The parameters of the VT100 terminal should be set as
follows:
• 9600 Baud
• No parity
• 8 Data bits
• 1 Stop bits
• No Flow Control
Windows HyperTerminal
Windows HyperTerminal can be used as a VT100
terminal emulation program. Open HyperTerminal by
selecting
Programs/Accessories/HyperTerminal
to the
section of HyperTerminal for additional
Help
information.
4
To ensure proper display background, select
VT100 terminal emulation under
Password and User ID
Password protection is factory enabled. If password
protection is enabled, the SCU will display the logon
screen, and a valid account name and password are
required to access menus. The factory default account
names and default passwords (both are case sensitive)
are displayed in

Table 3. Account Names and Passwords

Account
Name
ADMIN
READONLY
READWRITE
TEST
The Account Name and Password are to be
entered in all capital letters.
Menu Navigation
The following subsection describes the SHDSL T1/E1
LTU menus. Most menu selections are made by typing
the corresponding number and then pressing
the wrong selection is made, pressing
the previous screen. The Question Mark (
at any time to display a list of menu commands.
Main Menu
The Total Access Main menu allows the user to access
the module for various functions such as provisioning,
status, alarms, and performance monitoring.
. Refer
The menu tree in
provisioning, performance, and test access point in the
SHDSL T1/E1 menu system.
Table 4
lists the complete set of configurable options
with settings and factory default values.
Issue 1, August 2003
NOTE
Settings
Table
3.
Default
Access
Password
Rights
PASSWORD
Administration Access
PASSWORD
Read Access only
PASSWORD
Read and Write
Access
PASSWORD
Read and Test Access
NOTE
E
SC
?
Figure 3
illustrates the path to every
61182210L1-5A
.
. If
E
NTER
will display
) can be used

Advertisement

Table of Contents
loading

This manual is also suitable for:

Total access shdsl t1Total access shdsl e1

Table of Contents