Troubleshooting
Troubleshooting
Problem
Little or no resin (A) output
Little or no hardener (B) output
The mixed fluid will not flush out
8
1. Relieve the pressure before you check or service
2. Check all possible causes and solutions in the
Cause
The fluid inlet is plugged.
The fluid supply container is empty.
The fluid inlet is plugged.
The fluid supply container is empty.
There is hardened fluid in the mixing
chamber.
The solvent supply container is
empty.
The solvent is not compatible with
the fluid.
any system equipment.
Troubleshooting Chart before disassembling the
manifold.
Clean the inlet, remove the
obstruction.
Refill the fluid supply.
Clean the inlet, remove the
obstruction.
Refill the fluid supply.
Clean the chamber with a
compatible solvent; service it as
necessary.
Refill the solvent supply.
Change to a compatible solvent.
Solution
307400R