Error Codes
Error Code Error Icon Cause
E11
E50
E52
E53
E54
E55
E56
Key:
A
B
A key has been pressed for more than 30
seconds
Linear sensor fault, often caused if in Learn
mode and piston position measured is out-
side the expected range
Dispense valve is stuck open or one of the
material tanks is empty, leading to higher
dispensed quantity than requested
A piston stroke has taken more than 10 sec-
onds
This error code warns of the possibility of
inconsistent shots but will allow the
requested shot to occur. Shots requiring
less than 1/8 of a full piston stroke will trig-
ger this error code.
A shot has been requested that is above the
maximum allowable amount.
Learn mode failed to learn piston travel
range because:
1) Piston did not move during Learn mode
2) Linear sensor failure
A
B
Error Code
Error Icon
Possible Solutions
Check shot controller for stuck key
Replace shot controller
Check wiring and replace as necessary
Check linear sensor and replace as necessary
Learn mode will need to be used if linear
sensor is replaced
If dispense valve is stuck, the machine will auto-
matically attempt to release it
The amount dispensed will be more than
requested when this error occurs
Fill tank
Adjust E52 alarm delay time from setup
screen #4
Verify that the gun safety is off
Verify that the gun dispense valve is not stuck
closed
Verify adequate hydraulic or pneumatic pressure
to machine
Inspect for mechanical interference with the pis-
ton
Verify correct power to the proportioner piston
Request a larger shot
Verify that shot volume variation is ok
Request a smaller shot
Repeat Learn mode
Inspect the linear sensor and replace as neces-
sary