Troubleshooting
F
. 17: Error Alert Screen
IG
Error Codes
Error Code Error Icon Cause
E11
E50
E52
E53
E54
E55
E56
Key:
A
B
A key has been pressed for more than 30
seconds
Linear sensor fault, often caused if in Learn
mode and piston position measured is out-
side the expected range
Dispense valve is stuck open or one of the
material tanks is empty, leading to higher
dispensed quantity than requested
A piston stroke has taken more than 10 sec-
onds
This error code warns of the possibility of
inconsistent shots but will allow the
requested shot to occur. Shots requiring
less than 1/8 of a full piston stroke will trig-
ger this error code.
A shot has been requested that is above the
maximum allowable amount.
Learn mode failed to learn piston travel
range because:
1) Piston did not move during Learn mode
2) Linear sensor failure
A
B
Error Code
Error Icon
Possible Solutions
•
Check shot controller for stuck key
•
Replace shot controller
•
Check wiring and replace as necessary
•
Check linear sensor and replace as necessary
•
Learn mode will need to be used if linear
sensor is replaced
•
If dispense valve is stuck, the machine will auto-
matically attempt to release it
•
The amount dispensed will be more than
requested when this error occurs
•
Fill tank
•
Adjust E52 alarm delay time from setup
screen #4
•
Verify that the gun safety is off
•
Verify that the gun dispense valve is not stuck
closed
•
Verify adequate hydraulic or pneumatic pressure
to machine
•
Inspect for mechanical interference with the pis-
ton
•
Verify correct power to the proportioner piston
•
Request a larger shot
•
Verify that shot volume variation is ok
•
Request a smaller shot
•
Repeat Learn mode
•
Inspect the linear sensor and replace as neces-
sary
Troubleshooting