Figure 23: What Happened on Calibration (Track on x/y Plane while rotating)

Calibration process flow

Set phone to flat surface, far away from metals and magnetic fields
Set calibration mode on
Gently rotate phone until SW says "success or not"
Speed 10s/ round
Phone must be in all the time on same horizontal level
Check compass functionality after calibration
If calibration is not successfully, try again
If calibration fails again, change place
Try to find more magnetically undisturbed place

Compass digital values, limit values

Note: Sensitivity
0.5mGauss /digit (raw digit on x and y channels)
Limits:
Min x and min y