Ethernet Connection

When supporting up to two Gigabit operation (10/100/1000) use a CAT‐5 rated cable.
To connect Ethernet, perform the following steps:
1.Strip back the jacket of the subscriber Ethernet cable and connect the 4 pair twisted wires 
2. Route the Subscriber Ethernet wires through the cable entry on the bottom of the 
3. Insert the RJ‐45 connectors for each line. 
Refer to Figure 23 on page 36 for an example of what the final installation should look like.
6418770XGX-5B
to the RJ‐45 Plug using a RJ‐45 crimper. See Table 8 for straight through cable wiring stan‐
dard. There are two RJ‐45 jack holders molded into the enclosure (see Figure 22 on page 
34). 
enclosure. A tie wrap point is provided for wire management (see Figure 22 on page 34). 
Table 8. Wiring Standard
Pin Number
Color Code
1
White/Orange
2
Orange
3
White/Green
4
Blue
5
White/Blue
6
Green
7
White/Brown
8
Brown